In this reported research activity, a quantitatively 3D characterization at microscale of a CFRP reference composite with controlled porosity was performed by micro X-ray CT (mu XCT); the results were compared with the destructive acid digestion analyses, following the procedure reported in the standard test method (ASTM D 3171 15) used to determine the composites' porosity in General Aviation (GA). The mu XCT analyses revealed a pore content of 4.37%v and identified the components, respectively, in 66%w of carbon fibres and 34%w of matrix; all obtained results demonstrated a high correspondence to the theoretical values of porosity (5.0%v) and components (67%w of carbon fibre and 33%w of polymer matrix). Instead, a not complete correspondence of the measures obtained by acid digestion was reported: 4.36%v of porosity, but 57%w of carbon fibre and 43%w of matrix. Therefore, the conformity of the mu XCT results to the theoretical values demonstrated the feasibility and distinctiveness of the proposed NDT method for a rapid and reliable inspection of CRFP components used in GA in substitution of the standard DT and time-consuming digestion procedure. The proposed NDT inspection technique permitted not only the individuation and visualization in the reconstruction of the 3D analysed material of different components (e.g. pores, carbon fibres and polymer matrix) but also the 3D evaluation of the material composition with the identification and quantification of each constituent element.

Inspection of Carbon Fibre Reinforced Polymers: 3D identification and quantification of components by X-ray CT

Dilonardo E;Zarrelli M;Giannini C
2021

Abstract

In this reported research activity, a quantitatively 3D characterization at microscale of a CFRP reference composite with controlled porosity was performed by micro X-ray CT (mu XCT); the results were compared with the destructive acid digestion analyses, following the procedure reported in the standard test method (ASTM D 3171 15) used to determine the composites' porosity in General Aviation (GA). The mu XCT analyses revealed a pore content of 4.37%v and identified the components, respectively, in 66%w of carbon fibres and 34%w of matrix; all obtained results demonstrated a high correspondence to the theoretical values of porosity (5.0%v) and components (67%w of carbon fibre and 33%w of polymer matrix). Instead, a not complete correspondence of the measures obtained by acid digestion was reported: 4.36%v of porosity, but 57%w of carbon fibre and 43%w of matrix. Therefore, the conformity of the mu XCT results to the theoretical values demonstrated the feasibility and distinctiveness of the proposed NDT method for a rapid and reliable inspection of CRFP components used in GA in substitution of the standard DT and time-consuming digestion procedure. The proposed NDT inspection technique permitted not only the individuation and visualization in the reconstruction of the 3D analysed material of different components (e.g. pores, carbon fibres and polymer matrix) but also the 3D evaluation of the material composition with the identification and quantification of each constituent element.
2021
Carbon Fibre-Reinforced Polymer
X-ray Computed Tomography
3D Characterization
Non-Destructive Testing
Acid Digestion
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/460590
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact