The measurement of cosmic-ray individual spectra provides unique information regarding the origin and propagation of astro-particles. Due to the limited acceptance of current space experiments, protons and nuclei around the "knee"region (~1 PeV) can only be observed by ground based experiments. Thanks to an innovative design, the High Energy cosmic-Radiation Detection (HERD) facility will allow direct observation up to this energy region: the instrument is mainly based on a 3D segmented, isotropic and homogeneous calorimeter which properly measures the energy of particles coming from each direction and it will be made of about 7500 LYSO cubic crystals. The read-out of the scintillation light is done with two independent systems: the first one based on wave-length shifting fibers coupled to Intensified scientific CMOS cameras, the second one is made of two photo-diodes with different active areas connected to a custom front-end electronics. This photo-diode system is designed to achieve a huge dynamic range, larger than 107, while having a small power consumption, few mW per channel. Thanks to a good signal-to-noise ratio, the capability of a proper calibration, by using signals of both non-interacting and showering particles, is also guaranteed. In this paper, the current design and the performance obtained by several tests of the photo-diode read-out system are discussed.
Development of the photo-diode subsystem for the HERD calorimeter double-readout
Castellini, G.;Ricciarini, S.;
2022
Abstract
The measurement of cosmic-ray individual spectra provides unique information regarding the origin and propagation of astro-particles. Due to the limited acceptance of current space experiments, protons and nuclei around the "knee"region (~1 PeV) can only be observed by ground based experiments. Thanks to an innovative design, the High Energy cosmic-Radiation Detection (HERD) facility will allow direct observation up to this energy region: the instrument is mainly based on a 3D segmented, isotropic and homogeneous calorimeter which properly measures the energy of particles coming from each direction and it will be made of about 7500 LYSO cubic crystals. The read-out of the scintillation light is done with two independent systems: the first one based on wave-length shifting fibers coupled to Intensified scientific CMOS cameras, the second one is made of two photo-diodes with different active areas connected to a custom front-end electronics. This photo-diode system is designed to achieve a huge dynamic range, larger than 107, while having a small power consumption, few mW per channel. Thanks to a good signal-to-noise ratio, the capability of a proper calibration, by using signals of both non-interacting and showering particles, is also guaranteed. In this paper, the current design and the performance obtained by several tests of the photo-diode read-out system are discussed.File | Dimensione | Formato | |
---|---|---|---|
2-s2.0-85138207040_CR_ott.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
6.21 MB
Formato
Adobe PDF
|
6.21 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
2-s2.0-85138207040_IOP_OA_POSTPRINT.pdf
accesso aperto
Descrizione: This is the Author Accepted Manuscript (postprint) version of the following paper: Adriani, O. et al., "Development of the photo-diode subsystem for the HERD calorimeter double-readout", in JOURNAL OF INSTRUMENTATION, vol. 17 no. 9, 2022, https://dx.doi.org/10.1088/1748-0221/17/09/P09002
Tipologia:
Documento in Post-print
Licenza:
Creative commons
Dimensione
6.13 MB
Formato
Adobe PDF
|
6.13 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.