Asymmetric superconducting tunnel junctions with gaps Lambda 1 > Lambda(2) have been proven to show a peculiar nonlinear bipolar thermoelectric effect. This arises due to the spontaneous breaking of electron-hole symmetry in the system, and it is maximized at the matching-peak bias vertical bar V vertical bar = V-p = (Delta - Delta(2))/e. In this paper, we investigate the interplay of photon-assisted tunneling (PAT) and bipolar thermoelectric generation. In particular, we show how thermoelectricity, at the matching peak, is supported by photon absorption and emission processes at the frequency-shifted sidebands V = +/- V-p + n (h) over bar omega, n is an element of Z. This represents a sort of microwave-assisted thermoelectricity. We show the existence of multiple stable solutions, being associated with different photon sidebands, when a load is connected to the junction. Finally, we discuss how the nonlinear cooling effects are modified by the PAT. The proposed device can detect millimeter-wavelength signals by converting a temperature gradient into a thermoelectric current or voltage.
Microwave-Assisted Thermoelectricity in S-I-S ' Tunnel Junctions
Giazotto F;Braggio A
2023
Abstract
Asymmetric superconducting tunnel junctions with gaps Lambda 1 > Lambda(2) have been proven to show a peculiar nonlinear bipolar thermoelectric effect. This arises due to the spontaneous breaking of electron-hole symmetry in the system, and it is maximized at the matching-peak bias vertical bar V vertical bar = V-p = (Delta - Delta(2))/e. In this paper, we investigate the interplay of photon-assisted tunneling (PAT) and bipolar thermoelectric generation. In particular, we show how thermoelectricity, at the matching peak, is supported by photon absorption and emission processes at the frequency-shifted sidebands V = +/- V-p + n (h) over bar omega, n is an element of Z. This represents a sort of microwave-assisted thermoelectricity. We show the existence of multiple stable solutions, being associated with different photon sidebands, when a load is connected to the junction. Finally, we discuss how the nonlinear cooling effects are modified by the PAT. The proposed device can detect millimeter-wavelength signals by converting a temperature gradient into a thermoelectric current or voltage.File | Dimensione | Formato | |
---|---|---|---|
2023_PhysRevApplied_19_044024.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
2.5 MB
Formato
Adobe PDF
|
2.5 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
2211.04288v2(1).pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
Altro tipo di licenza
Dimensione
1.19 MB
Formato
Adobe PDF
|
1.19 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.