Urinalysis is commonly used as a screening tool for kidney disease. In many cases, the dipstick urine assay includes the assessment of albumin/protein and creatinine; consequently, the value of their ratio is available on the urine section report. Identification of albuminuria/proteinuria at early stages is an important issue to prevent or at least delay the onset of chronic kidney disease (CKD), kidney failure, and the progression of cardiovascular damage linked to the kidney's loss of function. Sensitive and specific diagnostic methods are required for the assessment of such an important biomarker: urine albumin, creatinine, and their ratio (ACR) measured with quantitative assays are considered the gold standard. Routine dipstick methods (more rapid and at a lower cost) are intended for wide population screening. The aim of our study was to verify the reliability of an automated urinalysis dipstick method by comparing the results with the quantitative test of creatinine and albumin performed on a clinical chemistry platform. The first-morning voids of 249 patients who arrived from different departments were analyzed in the Central Laboratory of the University Hospital Policlinico Umberto I in Rome. We found a good correlation between the two assays, even though we observed that the dipstick assessment tends to overestimate the ACR's value, disclosing a higher number of false positives if compared to the reference method. As an important novelty in this study, we analyzed our data considering age (starting from pediatric to geriatric patients) and sex as variables for a sub-stratification of the participants. Our results show that positive values need to be confirmed with quantitative methods, especially in women and younger people, and that from samples that resulted as diluted at the dipstick assay, the ACR's values can be obtained if they are reanalyzed with quantitative assays. Moreover, patients with microalbuminuria (ACR 30-300 mg/g) or severe albumin urinary excretion (ACR > 300 mg/g) should be reanalyzed using quantitative methods to obtain a more reliable calculation of the ACR.

Urine Dipstick Analysis on Automated Platforms: Is a Reliable Screening Tool for Proteinuria? An Experience from Umberto I Hospital in Rome

Fiore Marco
Co-ultimo
;
2023

Abstract

Urinalysis is commonly used as a screening tool for kidney disease. In many cases, the dipstick urine assay includes the assessment of albumin/protein and creatinine; consequently, the value of their ratio is available on the urine section report. Identification of albuminuria/proteinuria at early stages is an important issue to prevent or at least delay the onset of chronic kidney disease (CKD), kidney failure, and the progression of cardiovascular damage linked to the kidney's loss of function. Sensitive and specific diagnostic methods are required for the assessment of such an important biomarker: urine albumin, creatinine, and their ratio (ACR) measured with quantitative assays are considered the gold standard. Routine dipstick methods (more rapid and at a lower cost) are intended for wide population screening. The aim of our study was to verify the reliability of an automated urinalysis dipstick method by comparing the results with the quantitative test of creatinine and albumin performed on a clinical chemistry platform. The first-morning voids of 249 patients who arrived from different departments were analyzed in the Central Laboratory of the University Hospital Policlinico Umberto I in Rome. We found a good correlation between the two assays, even though we observed that the dipstick assessment tends to overestimate the ACR's value, disclosing a higher number of false positives if compared to the reference method. As an important novelty in this study, we analyzed our data considering age (starting from pediatric to geriatric patients) and sex as variables for a sub-stratification of the participants. Our results show that positive values need to be confirmed with quantitative methods, especially in women and younger people, and that from samples that resulted as diluted at the dipstick assay, the ACR's values can be obtained if they are reanalyzed with quantitative assays. Moreover, patients with microalbuminuria (ACR 30-300 mg/g) or severe albumin urinary excretion (ACR > 300 mg/g) should be reanalyzed using quantitative methods to obtain a more reliable calculation of the ACR.
2023
Istituto di Biochimica e Biologia Cellulare - IBBC
albumin
comparison between methods
creatinine
kidney
urine analysis
File in questo prodotto:
File Dimensione Formato  
247.pdf

accesso aperto

Licenza: Creative commons
Dimensione 3.08 MB
Formato Adobe PDF
3.08 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/462871
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact