: In HILO microscopy, a highly inclined and laminated light sheet is used to illuminate the sample, thus drastically reducing background fluorescence in wide-field microscopy, but maintaining the simplicity of the use of a single objective for both illumination and detection. Although the technique has become widely popular, particularly in single molecule and super-resolution microscopy, a limited understanding of how to finely shape the illumination beam and of how this impacts on the image quality complicates the setting of HILO to fit the experimental needs. In this work, we build up a simple and comprehensive guide to optimize the beam shape and alignment in HILO and to predict its performance in conventional fluorescence and super-resolution microscopy. We model the beam propagation through Gaussian optics and validate the model through far- and near-field experiments, thus characterizing the main geometrical features of the beam. Further, we fully quantify the effects of a progressive reduction of the inclined beam thickness on the image quality of both diffraction-limited and super-resolution images and we show that the most relevant impact is obtained by reducing the beam thickness to sub-cellular dimensions (< 3 µm). Based on this, we present a simple optical solution that exploits a rectangular slit to reduce the inclined beam thickness down to 2.6 µm while keeping a field-of-view dimension suited for cell imaging and allowing an increase in the number of localizations in super-resolution imaging of up to 2.6 folds.

Optimization of highly inclined illumination for diffraction-limited and super-resolution microscopy

Gardini L.
;
Pavone F. S.;
2023

Abstract

: In HILO microscopy, a highly inclined and laminated light sheet is used to illuminate the sample, thus drastically reducing background fluorescence in wide-field microscopy, but maintaining the simplicity of the use of a single objective for both illumination and detection. Although the technique has become widely popular, particularly in single molecule and super-resolution microscopy, a limited understanding of how to finely shape the illumination beam and of how this impacts on the image quality complicates the setting of HILO to fit the experimental needs. In this work, we build up a simple and comprehensive guide to optimize the beam shape and alignment in HILO and to predict its performance in conventional fluorescence and super-resolution microscopy. We model the beam propagation through Gaussian optics and validate the model through far- and near-field experiments, thus characterizing the main geometrical features of the beam. Further, we fully quantify the effects of a progressive reduction of the inclined beam thickness on the image quality of both diffraction-limited and super-resolution images and we show that the most relevant impact is obtained by reducing the beam thickness to sub-cellular dimensions (< 3 µm). Based on this, we present a simple optical solution that exploits a rectangular slit to reduce the inclined beam thickness down to 2.6 µm while keeping a field-of-view dimension suited for cell imaging and allowing an increase in the number of localizations in super-resolution imaging of up to 2.6 folds.
2023
Istituto Nazionale di Ottica - INO - Sede Secondaria di Sesto Fiorentino
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/467742
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ente

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact