Breath-hold divers may experience haemoptysis during diving. Central pooling of blood as well as compression of pulmonary gas content can damage the integrity of the blood-gas barrier, resulting in alveolar hemorrhage. The single-breath carbon monoxide test (DL,CO) was used to investigate the blood-gas barrier following diving. The study population consisted of 30 divers recruited from a training course. DL,CO levels were measured before diving and at 2, 10 and 25 min after the last of a series of four dives to depths of 10, 15, 20 and 30 m. When compared to pre-diving values, DL,CO values increased significantly at 2 min following diving in all subjects except one. Thereafter values progressively decreased toward baseline at 10 and 25 min in all subjects but one, while in four divers DL,CO values decreased below baseline. The early but transient increase in DL,CO levels shortly after diving supports the persistence of capillary pooling of red blood cells following emersion. Persistence at 25 min of high DL,CO values in one subject could be attributed by lung CT to extravasation of blood into the alveoli. Early or late DL,CO values >10% below baseline values suggest the presence of pulmonary edema. The relatively high prevalence of DL,CO alterations found suggests caution on the safety of breath-hold diving activities.

Time course of carbon monoxide transfer factor after breath-hold diving

Prediletto R;Fornai E;Catapano G;Passera M;Bedini R;L'Abbate A
2009

Abstract

Breath-hold divers may experience haemoptysis during diving. Central pooling of blood as well as compression of pulmonary gas content can damage the integrity of the blood-gas barrier, resulting in alveolar hemorrhage. The single-breath carbon monoxide test (DL,CO) was used to investigate the blood-gas barrier following diving. The study population consisted of 30 divers recruited from a training course. DL,CO levels were measured before diving and at 2, 10 and 25 min after the last of a series of four dives to depths of 10, 15, 20 and 30 m. When compared to pre-diving values, DL,CO values increased significantly at 2 min following diving in all subjects except one. Thereafter values progressively decreased toward baseline at 10 and 25 min in all subjects but one, while in four divers DL,CO values decreased below baseline. The early but transient increase in DL,CO levels shortly after diving supports the persistence of capillary pooling of red blood cells following emersion. Persistence at 25 min of high DL,CO values in one subject could be attributed by lung CT to extravasation of blood into the alveoli. Early or late DL,CO values >10% below baseline values suggest the presence of pulmonary edema. The relatively high prevalence of DL,CO alterations found suggests caution on the safety of breath-hold diving activities.
2009
Istituto di Fisiologia Clinica - IFC
gas exchange
diffusin capacity
lungs
breath Holding
diving
File in questo prodotto:
File Dimensione Formato  
prod_24190-doc_8952.pdf

non disponibili

Descrizione: Time course of carbon monoxide transfer factor after breath-hold diving
Dimensione 1.29 MB
Formato Adobe PDF
1.29 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/47007
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact