Secondary Ion Mass Spectrometry (SIMS) can provide distribution images of elements and molecular fragments with high sensitivity and spatial resolution. This study aims to exploit the potential of this modality as an imaging technique for biomedical applications. A model of image generation was developed and validated on experimental SIMS images. The model allowed for the selection of standard distance deviation (SDD) and nearest neighbor index (NNI) as suitable indices for the characterization of SIMS images, as they have been associated with sample morphology. Two regression models were proposed to correlate the SDD index and NNI with an index of effectiveness and acquisition parameters. The SDD index, due to its linear relationship with the image noise parameter, was less sensitive to noise. The model was then applied to study the effect of instrumental and analytical parameters, such as pre-sputtering time, on image generation.

An image formation model for Secondary Ion Mass Spectrometry imaging of biological tissue samples

Menichetti L;Kusmic C;Landini L;Positano V
2010-01-01

Abstract

Secondary Ion Mass Spectrometry (SIMS) can provide distribution images of elements and molecular fragments with high sensitivity and spatial resolution. This study aims to exploit the potential of this modality as an imaging technique for biomedical applications. A model of image generation was developed and validated on experimental SIMS images. The model allowed for the selection of standard distance deviation (SDD) and nearest neighbor index (NNI) as suitable indices for the characterization of SIMS images, as they have been associated with sample morphology. Two regression models were proposed to correlate the SDD index and NNI with an index of effectiveness and acquisition parameters. The SDD index, due to its linear relationship with the image noise parameter, was less sensitive to noise. The model was then applied to study the effect of instrumental and analytical parameters, such as pre-sputtering time, on image generation.
2010
Istituto di Fisiologia Clinica - IFC
Secondary Ion Mass Spectrometry
Point pattern distribution analysis
File in questo prodotto:
File Dimensione Formato  
prod_24288-doc_12674.pdf

non disponibili

Descrizione: An image formation model for Secondary Ion Mass Spectrometry imaging of biological tissue samples
Dimensione 1.43 MB
Formato Adobe PDF
1.43 MB Adobe PDF   Visualizza/Apri   Richiedi una copia