Background: Acute kidney injury (AKI) is common in patients with acute coronary syndromes (ACS) treated by percutaneous coronary intervention. Objectives: Contrast media (CM) volume minimization has been advocated for prevention of AKI. The DyeVert CM diversion system (Osprey Medical, Inc) is designed to reduce CM volume during coronary procedures. Methods: In this randomized, single-blind, investigator-driven clinical trial conducted in 4 Italian centers from February 4, 2020 to September 13, 2022, 550 participants with ACS were randomly assigned in a 1:1 ratio to the following: 1) the contrast volume reduction (CVR) group (n = 276), in which CM injection was handled by the CM diversion system; and 2) the control group (n = 274), in which a conventional manual or automatic injection syringe was used. The primary endpoint was the rate of AKI, defined as a serum creatinine (sCr) increase ≥0.3 mg/dL within 48 hours after CM exposure. Results: There were 412 of 550 (74.5%) participants with ST-segment elevation myocardial infarction (211 of 276 [76.4%] in the CVR group and 201 of 274 [73.3%] in the control group). The CM volume was lower in the CVR group (95 ± 30 mL vs 160 ± 23 mL; P < 0.001). Seven participants (1 in the CVR group and 6 in the control group) did not have postprocedural sCr values. AKI occurred in 44 of 275 (16%) participants in the CVR group and in 65 of 268 (24.3%) participants in the control group (relative risk: 0.66; 95% CI: 0.47-0.93; P = 0.018). Conclusions: CM volume reduction obtained using the CM diversion system is effective for prevention of AKI in patients with ACS undergoing invasive procedures. (REnal Insufficiency Following Contrast MEDIA Administration TriaL IV [REMEDIALIV]: NCT04714736).

Kidney Injury After Minimal Radiographic Contrast Administration in Patients With Acute Coronary Syndromes

Quintavalle, Cristina;
2024

Abstract

Background: Acute kidney injury (AKI) is common in patients with acute coronary syndromes (ACS) treated by percutaneous coronary intervention. Objectives: Contrast media (CM) volume minimization has been advocated for prevention of AKI. The DyeVert CM diversion system (Osprey Medical, Inc) is designed to reduce CM volume during coronary procedures. Methods: In this randomized, single-blind, investigator-driven clinical trial conducted in 4 Italian centers from February 4, 2020 to September 13, 2022, 550 participants with ACS were randomly assigned in a 1:1 ratio to the following: 1) the contrast volume reduction (CVR) group (n = 276), in which CM injection was handled by the CM diversion system; and 2) the control group (n = 274), in which a conventional manual or automatic injection syringe was used. The primary endpoint was the rate of AKI, defined as a serum creatinine (sCr) increase ≥0.3 mg/dL within 48 hours after CM exposure. Results: There were 412 of 550 (74.5%) participants with ST-segment elevation myocardial infarction (211 of 276 [76.4%] in the CVR group and 201 of 274 [73.3%] in the control group). The CM volume was lower in the CVR group (95 ± 30 mL vs 160 ± 23 mL; P < 0.001). Seven participants (1 in the CVR group and 6 in the control group) did not have postprocedural sCr values. AKI occurred in 44 of 275 (16%) participants in the CVR group and in 65 of 268 (24.3%) participants in the control group (relative risk: 0.66; 95% CI: 0.47-0.93; P = 0.018). Conclusions: CM volume reduction obtained using the CM diversion system is effective for prevention of AKI in patients with ACS undergoing invasive procedures. (REnal Insufficiency Following Contrast MEDIA Administration TriaL IV [REMEDIALIV]: NCT04714736).
2024
Istituto di Endocrinologia e Oncologia Sperimentale ''G. Salvatore'' - IEOS
contrast media
myocardial infarction
percutaneous coronary intervention
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/472608
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ente

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact