A Ce-radical scavenger-based perfluorosulfonic acid (PFSA) Aquivion® membrane (C98 05S-RSP) was developed and assessed for polymer electrolyte membrane (PEM) electrolyser applications. The membrane, produced by Solvay Specialty Polymers, had an equivalent weight (EW) of 980 g/eq and a thickness of 50 μm to reduce ohmic losses at a high current density. The electrochemical properties and gas crossover through the membrane were evaluated upon the formation of a membrane-electrode assembly (MEA) in a range of temperatures between 30 and 90 °C and at various differential pressures (ambient, 10 and 20 bars). Bare extruded (E98 05S) and reinforced (R98 05S) PFSA Aquivion® membranes with similar EWs and thicknesses were assessed for comparison in terms of their performance, stability and hydrogen crossover under the same operating conditions. The method used for the membrane manufacturing significantly influenced the interfacial properties, with the electrodes affecting the polarisation resistance and H2 permeation in the oxygen stream, as well as the degradation rate, as observed in the durability studies.
Ce-radical Scavenger-Based Perfluorosulfonic Acid Aquivion® Membrane for Pressurised PEM Electrolysers
Stefania Siracusano
;Fausta Giacobello;Antonino Arico
2023
Abstract
A Ce-radical scavenger-based perfluorosulfonic acid (PFSA) Aquivion® membrane (C98 05S-RSP) was developed and assessed for polymer electrolyte membrane (PEM) electrolyser applications. The membrane, produced by Solvay Specialty Polymers, had an equivalent weight (EW) of 980 g/eq and a thickness of 50 μm to reduce ohmic losses at a high current density. The electrochemical properties and gas crossover through the membrane were evaluated upon the formation of a membrane-electrode assembly (MEA) in a range of temperatures between 30 and 90 °C and at various differential pressures (ambient, 10 and 20 bars). Bare extruded (E98 05S) and reinforced (R98 05S) PFSA Aquivion® membranes with similar EWs and thicknesses were assessed for comparison in terms of their performance, stability and hydrogen crossover under the same operating conditions. The method used for the membrane manufacturing significantly influenced the interfacial properties, with the electrodes affecting the polarisation resistance and H2 permeation in the oxygen stream, as well as the degradation rate, as observed in the durability studies.File | Dimensione | Formato | |
---|---|---|---|
polymers-15-03906.pdf
accesso aperto
Descrizione: Articolo in rivista
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
2.65 MB
Formato
Adobe PDF
|
2.65 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.