Purpose: To assess the feasibility of theranostics to determine the riboflavin concentration in the cornea using clinically available ophthalmic formulations during epithelium-off (epi-off) and transepithelial (epi-on) corneal cross-linking procedures. Methods: Thirty-two eye bank human donor corneas were equally randomized in eight groups; groups 1 to 3 and groups 4 to 8 underwent epi-off and epi-on delivery of riboflavin respectively. Riboflavin ophthalmic solutions were applied onto the cornea according to the manufacturers' instructions. The amount of riboflavin into the cornea was estimated, at preset time intervals during imbibition time, using theranostic UV-A device (C4V CHROMO4VIS, Regensight srl, Italy) and expressed as riboflavin score (d.u.). Measurements of corneal riboflavin concentration (expressed as µg/cm3) were also performed by spectroscopy absorbance technique (AvaLight-DH-S-BAL, Avantes) for external validation of theranostic measurements. Results: At the end of imbibition time in epi-off delivery protocols, the average riboflavin score ranged from 0.77 ± 0.38 (the average corneal riboflavin concentration was 213 ± 190 µg/cm3) to 1.79 ± 0.07 (554 ± 103 µg/cm3). In epi-on delivery protocols, the average riboflavin score ranged from 0.17 ± 0.01 to 0.67 ± 0.19 (corneal riboflavin concentration ranged from 6 ± 5 µg/cm3 to 122 ± 39 µg/cm3) at the end of imbibition time. A statistically significant linear correlation (P ≤ 0.05) was found between the theranostic and spectrophotometry measurements in all groups. Conclusions: Real-time theranostic imaging provided an accurate strategy for assessing permeation of riboflavin into the human cornea during the imbibition phase of corneal cross-linking, regardless of delivery protocol. A large variability in corneal riboflavin concentration exists between clinically available ophthalmic formulations both in epi-off and epi-on delivery protocols.

Real-time monitoring of riboflavin concentration using different clinically available ophthalmic formulations for epi-off and epi-on corneal cross-linking

Bernava Giuseppe;Lombardo Giuseppe
Ultimo
Writing – Review & Editing
2024

Abstract

Purpose: To assess the feasibility of theranostics to determine the riboflavin concentration in the cornea using clinically available ophthalmic formulations during epithelium-off (epi-off) and transepithelial (epi-on) corneal cross-linking procedures. Methods: Thirty-two eye bank human donor corneas were equally randomized in eight groups; groups 1 to 3 and groups 4 to 8 underwent epi-off and epi-on delivery of riboflavin respectively. Riboflavin ophthalmic solutions were applied onto the cornea according to the manufacturers' instructions. The amount of riboflavin into the cornea was estimated, at preset time intervals during imbibition time, using theranostic UV-A device (C4V CHROMO4VIS, Regensight srl, Italy) and expressed as riboflavin score (d.u.). Measurements of corneal riboflavin concentration (expressed as µg/cm3) were also performed by spectroscopy absorbance technique (AvaLight-DH-S-BAL, Avantes) for external validation of theranostic measurements. Results: At the end of imbibition time in epi-off delivery protocols, the average riboflavin score ranged from 0.77 ± 0.38 (the average corneal riboflavin concentration was 213 ± 190 µg/cm3) to 1.79 ± 0.07 (554 ± 103 µg/cm3). In epi-on delivery protocols, the average riboflavin score ranged from 0.17 ± 0.01 to 0.67 ± 0.19 (corneal riboflavin concentration ranged from 6 ± 5 µg/cm3 to 122 ± 39 µg/cm3) at the end of imbibition time. A statistically significant linear correlation (P ≤ 0.05) was found between the theranostic and spectrophotometry measurements in all groups. Conclusions: Real-time theranostic imaging provided an accurate strategy for assessing permeation of riboflavin into the human cornea during the imbibition phase of corneal cross-linking, regardless of delivery protocol. A large variability in corneal riboflavin concentration exists between clinically available ophthalmic formulations both in epi-off and epi-on delivery protocols.
2024
Istituto per i Processi Chimico-Fisici - IPCF
Corneal cross-linking
Riboflavin
Theranostics
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/474306
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ente

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact