The purpose of this study is to evaluate the degree of PCB contamination of Venice lagoon water. The PCB determination was made on the filtrate ("dissolved PCBs") and on the particulate collected on the filters ("particulate PCBs") by continuous liquid–liquid extraction and sonication, respectively, and by HRGC-LRMS analysis. An estimation of the procedural and "working" blanks was also made. Water samples were collected at six sites, selected to represent all the pollution situations present in the lagoon, and at a site in the Adriatic Sea. The range of the total sum ("dissolved plus particulate") of 49 congener concentrations falls between 355 and 1868pgl-1; the "dissolved" fraction concentrations (250–792pgl-1) are greater at six sites than that of the "particulate" fraction (105–1273pgl-1). Chemometric analyses suggest that the PCB congener pattern in the Venice Lagoon is different from that in the Adriatic Sea.

Determination of Polychlorobiphenyl congeners (PCBs) in the surface water of the Venice Lagoon.

Gambaro A;Piazza R;
2005

Abstract

The purpose of this study is to evaluate the degree of PCB contamination of Venice lagoon water. The PCB determination was made on the filtrate ("dissolved PCBs") and on the particulate collected on the filters ("particulate PCBs") by continuous liquid–liquid extraction and sonication, respectively, and by HRGC-LRMS analysis. An estimation of the procedural and "working" blanks was also made. Water samples were collected at six sites, selected to represent all the pollution situations present in the lagoon, and at a site in the Adriatic Sea. The range of the total sum ("dissolved plus particulate") of 49 congener concentrations falls between 355 and 1868pgl-1; the "dissolved" fraction concentrations (250–792pgl-1) are greater at six sites than that of the "particulate" fraction (105–1273pgl-1). Chemometric analyses suggest that the PCB congener pattern in the Venice Lagoon is different from that in the Adriatic Sea.
2005
Istituto per la Dinamica dei Processi Ambientali - IDPA - Sede Venezia
Inglese
50
167
174
Venice lagoon
Water
Pollution
PCBs
GCMS
In this paper a methodology (Hermans et al., 1992) for the determination of PCB congener concentrations in sea water samples has been revised and used for the evaluation of the degree of contamination of Venice Lagoon water by this class of compounds. A comparison with the PCB congener concentration found in the Adriatic Sea is also made.
5
info:eu-repo/semantics/article
262
Moret, I; Gambaro, A; Piazza, R; Ferrari, S; Manodori, L
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/48000
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact