Inductively coupled plasma mass spectrometry (ICP-MS) is a suitable tool for multi-element analysis at low concentration levels. Rare earth element (REE) determinations in standard reference materials and small volumes of molten ice core samples from Antarctica have been performed with an ICP-time of flight-MS (ICP-TOF-MS) system. Recovery rates for REE in e.g. SPS-SW1 amounted to similar to 103%, and the relative standard deviations were 3.4% for replicate analysis at REE concentrations in the lower ng L-1 range. Analyses of REE concentrations in Antarctic ice core samples showed that the ICP-TOF-MS technique meets the demands of restricted sample mass. The data obtained are in good agreement with ICP-quadrupole-MS (ICP-Q-MS) and ICP-sector field-MS (ICP-SF-MS) results. The ICP-TOF-MS system determines accurately and precisely REE concentrations exceeding 5 ng L-1 while between 0.5 and 5 ng L-1 accuracy and precision are element dependent. (c) 2008 Elsevier B.V All rights reserved.

Rare earth elements determined in Antarctic ice by inductively coupled plasma -Time of flight, quadrupole and sector field-mass spectrometry: An inter-comparison study

Barbante C;
2008

Abstract

Inductively coupled plasma mass spectrometry (ICP-MS) is a suitable tool for multi-element analysis at low concentration levels. Rare earth element (REE) determinations in standard reference materials and small volumes of molten ice core samples from Antarctica have been performed with an ICP-time of flight-MS (ICP-TOF-MS) system. Recovery rates for REE in e.g. SPS-SW1 amounted to similar to 103%, and the relative standard deviations were 3.4% for replicate analysis at REE concentrations in the lower ng L-1 range. Analyses of REE concentrations in Antarctic ice core samples showed that the ICP-TOF-MS technique meets the demands of restricted sample mass. The data obtained are in good agreement with ICP-quadrupole-MS (ICP-Q-MS) and ICP-sector field-MS (ICP-SF-MS) results. The ICP-TOF-MS system determines accurately and precisely REE concentrations exceeding 5 ng L-1 while between 0.5 and 5 ng L-1 accuracy and precision are element dependent. (c) 2008 Elsevier B.V All rights reserved.
2008
Istituto per la Dinamica dei Processi Ambientali - IDPA - Sede Venezia
ultra trace element analysis
inductively coupled plasma-time of flight-mass spectrometry
rare earth elements
Antarctic ice
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/48168
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact