Escherichia coli (E. coli) is one of the most commonly adopted indicators for the determination of the microbiological quality in water and treated wastewater. Two main types of methods are used for the enumeration of this faecal indicator: membrane filtration (MF) and enzyme substrate tests. For both types, several substrates based on the β-D-glucuronidase activity have been commercialized. The specificity of this enzyme for E. coli bacteria has generated considerable use of methods that identify the β-D-glucuronidase activity as a definite indication of the presence of E. coli, without any further confirmation. This approach has been recently questioned for the application to wastewater. The present study compares two methods belonging to the above-mentioned types for the enumeration of E. coli in wastewater: MF with Tryptone Bile X-glucuronide agar and the Colilert®-18 test. Confirmation tests showed low average percentages of false positives and false negatives for both enumeration methods (between 4 and 11%). Moreover, the counting capabilities of these two methods were compared for a set of 70 samples of wastewater having different origins and degrees of treatment. Statistical analysis showed that the Colilert®-18 test allowed on average for a significantly higher recovery of E. coli.
Identification of the faecal indicator Escherichia coli in wastewater through the β-D-glucuronidase activity: comparison between two enumeration methods, membrane filtration with TBX agar, and Colilert®-18
P. Vergine
Primo
;C. SalernoSecondo
;E. Barca;G. Berardi;A. PolliceUltimo
2016
Abstract
Escherichia coli (E. coli) is one of the most commonly adopted indicators for the determination of the microbiological quality in water and treated wastewater. Two main types of methods are used for the enumeration of this faecal indicator: membrane filtration (MF) and enzyme substrate tests. For both types, several substrates based on the β-D-glucuronidase activity have been commercialized. The specificity of this enzyme for E. coli bacteria has generated considerable use of methods that identify the β-D-glucuronidase activity as a definite indication of the presence of E. coli, without any further confirmation. This approach has been recently questioned for the application to wastewater. The present study compares two methods belonging to the above-mentioned types for the enumeration of E. coli in wastewater: MF with Tryptone Bile X-glucuronide agar and the Colilert®-18 test. Confirmation tests showed low average percentages of false positives and false negatives for both enumeration methods (between 4 and 11%). Moreover, the counting capabilities of these two methods were compared for a set of 70 samples of wastewater having different origins and degrees of treatment. Statistical analysis showed that the Colilert®-18 test allowed on average for a significantly higher recovery of E. coli.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.