The osteointegration phase of BAHA® fixture was assessed via electrical impedance spectroscopy in BAHA® implantees. Measurements were carried out by using a prototype device and were correlated with previously published histological data obtained at certain times after surgery, i.e. 1-2 days, 1 week, 1 and 3 months. Module variations of impedance spectra were found to be in agreement with the different pathophysiological conditions of bone ingrowth. The proposed methodology has shown to be promisingly reliable to properly monitor BAHA fixture osteointegration.

The osteointegration phase of BAHA(R) fixture was assessed via electrical impedance spectroscopy in BAHA(R) implantees. Measurements were carried out by using a prototype device and were correlated with previously published histological data obtained at certain times after surgery, i.e. 1-2 days, 1 week, 1 and 3 months. Module variations of impedance spectra were found to be in agreement with the different pathophysiological conditions of bone ingrowth. The proposed methodology has shown to be promisingly reliable to properly monitor BAHA fixture osteointegration.

Monitoring of Fixture Osteointegration after BAHA(R) Implantation

Clemente F;
2010

Abstract

The osteointegration phase of BAHA(R) fixture was assessed via electrical impedance spectroscopy in BAHA(R) implantees. Measurements were carried out by using a prototype device and were correlated with previously published histological data obtained at certain times after surgery, i.e. 1-2 days, 1 week, 1 and 3 months. Module variations of impedance spectra were found to be in agreement with the different pathophysiological conditions of bone ingrowth. The proposed methodology has shown to be promisingly reliable to properly monitor BAHA fixture osteointegration.
2010
Istituto di Biostrutture e Bioimmagini - IBB - Sede Napoli
INGEGNERIA BIOMEDICA
The osteointegration phase of BAHA® fixture was assessed via electrical impedance spectroscopy in BAHA® implantees. Measurements were carried out by using a prototype device and were correlated with previously published histological data obtained at certain times after surgery, i.e. 1-2 days, 1 week, 1 and 3 months. Module variations of impedance spectra were found to be in agreement with the different pathophysiological conditions of bone ingrowth. The proposed methodology has shown to be promisingly reliable to properly monitor BAHA fixture osteointegration.
Electric impedance spectroscopy
Osteointegration
ENDOSSEOUS IMPLANTS
BONE
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/48258
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? ND
social impact