The intervertebral disc (IVD) has a central nucleus pulposus (NP) able to resist compressive loads and an outer annulus fibrosus which withstands tension and gives mechanical strength. The tissue engineering of a disc substitute represents a challenge from mechanical and biological (nutrition and transport) points of view. Two hyaluronanderived polymeric substitute materials, HYAFF_R 120, an ester and HYADD_R 3, an amide were injected into the NP of the lumbar spine of female pigs (11.1 ± 1.0 Kg) in which a nucleotomy had also been performed. Homologous bone marrow stem cells, obtained from the bone marrow three weeks before spinal surgery, were included in the HYADD_R 3 material (1 × 106 cells/ml). Two lumbar discs were operated in each animal. Control discs received a nucleotomy only. The animals were killed after 6 weeks and the lumbar spines recovered for histopathological study. Nucleotomy resulted in loss of normal IVD structure with narrowing, fibrous tissue replacement and disruption of the bony end-plates (4/4). By contrast, both HYAFF_R 120 (4/4) and HYADD 3_R (4/4) treatment prevented this change. The injected discs had a central NP-like region which had a close similarity to the normal biconvex structure and contained viable chondrocytes forming matrix like that of normal disc.

Tissue engineered intervertebral disc repair in pig using injectable polymers

L Ambrosio
2007

Abstract

The intervertebral disc (IVD) has a central nucleus pulposus (NP) able to resist compressive loads and an outer annulus fibrosus which withstands tension and gives mechanical strength. The tissue engineering of a disc substitute represents a challenge from mechanical and biological (nutrition and transport) points of view. Two hyaluronanderived polymeric substitute materials, HYAFF_R 120, an ester and HYADD_R 3, an amide were injected into the NP of the lumbar spine of female pigs (11.1 ± 1.0 Kg) in which a nucleotomy had also been performed. Homologous bone marrow stem cells, obtained from the bone marrow three weeks before spinal surgery, were included in the HYADD_R 3 material (1 × 106 cells/ml). Two lumbar discs were operated in each animal. Control discs received a nucleotomy only. The animals were killed after 6 weeks and the lumbar spines recovered for histopathological study. Nucleotomy resulted in loss of normal IVD structure with narrowing, fibrous tissue replacement and disruption of the bony end-plates (4/4). By contrast, both HYAFF_R 120 (4/4) and HYADD 3_R (4/4) treatment prevented this change. The injected discs had a central NP-like region which had a close similarity to the normal biconvex structure and contained viable chondrocytes forming matrix like that of normal disc.
2007
MATERIALI COMPOSITI E BIOMEDICI
hyaluronan esters
tissue engineering
biomaterials
intervertebral disc
in vivo biocompatibility
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/48603
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 91
social impact