This study describes a straightforward and non-destructive interferometric technique for measuring the propagation loss in single-mode optical glass waveguides by exploiting a Fabry–Perot cavity effect. The experiment involves coupling a powerful tunable laser source to a single-mode waveguide that is being tested, then using a detector to analyze the transmission fringes of that source after coating the glass end facets with highly reflective coating. Our first experiment, which used a 22.4-mm-long fabricated waveguide on Non-Iox Gorilla glass to demonstrate the technique, resulted in a propagation loss of 0.49 dB/cm at a transmitting wavelength of about 1575 nm, which is completely consistent with the value obtained by a conventional characterization method. The measurement procedure is also independent from the coupling losses, making the characterization easier and reliable after the manufacturing just with a reversible deposition process on the sample under testing.
Improvement in measuring losses by interferometric technique for glass waveguides produced by femtosecond laser writing
Osellame, Roberto;
2023
Abstract
This study describes a straightforward and non-destructive interferometric technique for measuring the propagation loss in single-mode optical glass waveguides by exploiting a Fabry–Perot cavity effect. The experiment involves coupling a powerful tunable laser source to a single-mode waveguide that is being tested, then using a detector to analyze the transmission fringes of that source after coating the glass end facets with highly reflective coating. Our first experiment, which used a 22.4-mm-long fabricated waveguide on Non-Iox Gorilla glass to demonstrate the technique, resulted in a propagation loss of 0.49 dB/cm at a transmitting wavelength of about 1575 nm, which is completely consistent with the value obtained by a conventional characterization method. The measurement procedure is also independent from the coupling losses, making the characterization easier and reliable after the manufacturing just with a reversible deposition process on the sample under testing.| File | Dimensione | Formato | |
|---|---|---|---|
|
(2023) Interferometric loss measurement - OC.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
947.51 kB
Formato
Adobe PDF
|
947.51 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


