H2 sensing performance of novel Pd–Pt alloy films has been compared with those obtained by using Pd films and H2-reducted PdO films. Two different detecting systems were used to measure the hydrogenation and de-hydrogenation phases with a H2 concentration of both 5% v/v nitrogen and 1% v/v nitrogen at room temperature. The sensitivity loss observed for the Pd–Pt alloy and H2-reducted PdO samples with respect to pure Pd samples can be explained in terms of the reduction in the lattice constant and interstitial volume due to the Pt addition, which determine a decrement of hydrogen atoms penetrating in the films. On the other hand, results show an improvement in time -response for Pd–Pt alloy and H2-reducted PdO films with respect to pure Pd ones, presumably due to the increase of its permeability to H2. Moreover, the sensing measurements repeated after 60 days show that the Pd–Pt alloy films, unlike the Pd-based ones, fully preserve their performances, demonstrating the advantage of the Pt inclusion for stability purposes when the samples are stored upon humidity.

Room-temperature sensing performance of hydrogen using palladium-based film by optical setup

Corso, Alain J.
Methodology
;
Tessarolo, Enrico
Membro del Collaboration Group
;
Pelizzo, Maria G.
Conceptualization
2021

Abstract

H2 sensing performance of novel Pd–Pt alloy films has been compared with those obtained by using Pd films and H2-reducted PdO films. Two different detecting systems were used to measure the hydrogenation and de-hydrogenation phases with a H2 concentration of both 5% v/v nitrogen and 1% v/v nitrogen at room temperature. The sensitivity loss observed for the Pd–Pt alloy and H2-reducted PdO samples with respect to pure Pd samples can be explained in terms of the reduction in the lattice constant and interstitial volume due to the Pt addition, which determine a decrement of hydrogen atoms penetrating in the films. On the other hand, results show an improvement in time -response for Pd–Pt alloy and H2-reducted PdO films with respect to pure Pd ones, presumably due to the increase of its permeability to H2. Moreover, the sensing measurements repeated after 60 days show that the Pd–Pt alloy films, unlike the Pd-based ones, fully preserve their performances, demonstrating the advantage of the Pt inclusion for stability purposes when the samples are stored upon humidity.
2021
Istituto di fotonica e nanotecnologie - IFN - Sede Secondaria Padova
hydrogen detection, palladium-based film, palladium–platinum alloy film, optical sensor
File in questo prodotto:
File Dimensione Formato  
11_Yao_Room_OA_2020_4.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/488742
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact