: A superconducting quantum magnetometer for high-sensitivity applications has been developed by exploiting the flux focusing of the superconducting loop. Unlike conventional dc SQUID magnetometers that use a superconducting flux transformer or a multiloop design, in this case, a very simple design has been employed. It consists of a bare dc SQUID with a large washer-shaped superconducting ring in order to guarantee a magnetic field sensitivity BΦ less than one nT/Φ0. The degradation of the characteristics of the device due to an inevitable high value of the inductance parameter βL was successfully compensated by damping the inductance of the dc SQUID. The size of the magnetometer, coinciding with that of the washer, is 5 × 5 mm2 and the spectral density of the magnetic field noise is 8 fT/√Hz with a low frequency noise knee of two Hz. The excellent performance of this simple magnetometer makes it usable for all high-sensitivity applications including magnetoencephalography.

Superconducting Quantum Magnetometer Based on Flux Focusing Effect for High-Sensitivity Applications

Antonio Vettoliere
Primo
;
Carmine Granata
Ultimo
2024

Abstract

: A superconducting quantum magnetometer for high-sensitivity applications has been developed by exploiting the flux focusing of the superconducting loop. Unlike conventional dc SQUID magnetometers that use a superconducting flux transformer or a multiloop design, in this case, a very simple design has been employed. It consists of a bare dc SQUID with a large washer-shaped superconducting ring in order to guarantee a magnetic field sensitivity BΦ less than one nT/Φ0. The degradation of the characteristics of the device due to an inevitable high value of the inductance parameter βL was successfully compensated by damping the inductance of the dc SQUID. The size of the magnetometer, coinciding with that of the washer, is 5 × 5 mm2 and the spectral density of the magnetic field noise is 8 fT/√Hz with a low frequency noise knee of two Hz. The excellent performance of this simple magnetometer makes it usable for all high-sensitivity applications including magnetoencephalography.
2024
Istituto di Scienze Applicate e Sistemi Intelligenti "Eduardo Caianiello" - ISASI
Josephson junctions
dc SQUID
integrated device
magnetic field noise
magnetometer
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/510221
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ente

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact