The work investigates the feasibility of harmonic analysis implementation on smart meter microcontroller devices, according to IEC 61000-4-30 Class A and IEC 61000-4-7 Class I requirements. The final aim was to evaluate to what extent Class I harmonic analysis can be integrated into existing low-cost hardware platforms for smart metering, which normally have limited hardware features, especially concerning the ADC and the possibility of varying the sampling frequency with high resolution, according to the power system signal frequency. An extended experimental characterization is carried out on a case study device, aimed at analyzing its performances in terms of both measurement accuracy and computational burden. To increase metrological ADC behavior and decrease computational costs, sampling strategies and optimized interpolation algorithm have been implemented and tested verifying the feasibility of harmonic analysis implementation on smart meter microcontroller devices, according to IEC 61000-4-30 Class A and IEC 61000-4-7 Class I requirements.

Processing techniques for metrological improvement of low-cost smart meter hardware solution for IEC 61000-4-7 Class I harmonics measurements

Di Cara D.;Guaiana S.;Panzavecchia N.;TINE' G.
2024

Abstract

The work investigates the feasibility of harmonic analysis implementation on smart meter microcontroller devices, according to IEC 61000-4-30 Class A and IEC 61000-4-7 Class I requirements. The final aim was to evaluate to what extent Class I harmonic analysis can be integrated into existing low-cost hardware platforms for smart metering, which normally have limited hardware features, especially concerning the ADC and the possibility of varying the sampling frequency with high resolution, according to the power system signal frequency. An extended experimental characterization is carried out on a case study device, aimed at analyzing its performances in terms of both measurement accuracy and computational burden. To increase metrological ADC behavior and decrease computational costs, sampling strategies and optimized interpolation algorithm have been implemented and tested verifying the feasibility of harmonic analysis implementation on smart meter microcontroller devices, according to IEC 61000-4-30 Class A and IEC 61000-4-7 Class I requirements.
2024
Istituto di iNgegneria del Mare - INM (ex INSEAN) - Sede Secondaria Palermo
Power system measurements, Harmonic analysis, IEC 61000-4-30, IEC 61000-4-7, Power quality
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/511088
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact