Background: Vascular complications are frequently reported after electrophysiological (EP) procedures. Ultrasound (US) guidance during femoral vein cannulation has shown to reduce vascular damage related to unsuccessful attempts.The aim of our study is to define, under ultrasound guidance,anatomical and technical predictors of successful femoral vein cannulation in a cohort of patients undergoing EP procedures. Material and Methods: From December 2015 to January 2018, 192 patients (mean age 63,1±15,9 years, M:F=118:74) undergoing EP procedures were enrolled in the study. US-guided approach to femoral vessels cannulation was used in all subjects by four untrained operators. Femoral vein and artery depths and diameters were measured in all patients. Unsuccessful attempts (UA) and time to successful cannulation (TSC) were also calculated. Results: Vein and artery depths correlated with body weight (r=0.38 and 0.39, p=0.00), body mass index (r=0.53 and 0.50, p=0.00), and body surface area (r=0.25 and 0.28, p=0.00). Interestingly, the number of UA positively correlated with vein depth (r=0.23, p=0.01 for the right side and r=0.33, p=0.00 for the left side). Linear regression analysis showed that both vein depth (ß=0.42, p=0.001) andoperator training (ß=-0.75,p=0.00) were independently associated with UA. Conclusions: Anthropometric features, namely BMI and BSA, may provide information about femoral vein/artery anatomy in patients undergoing EP procedures. Patients with high BMI have deeper and larger veins, however only vein depth is a determinant of successful cannulation. Numbers of UA and TSC significantly decrease with operators training.
Predictors of successful ultrasound guided femoral vein cannulation in electrophysiological procedures
Scalese Marco;
2018
Abstract
Background: Vascular complications are frequently reported after electrophysiological (EP) procedures. Ultrasound (US) guidance during femoral vein cannulation has shown to reduce vascular damage related to unsuccessful attempts.The aim of our study is to define, under ultrasound guidance,anatomical and technical predictors of successful femoral vein cannulation in a cohort of patients undergoing EP procedures. Material and Methods: From December 2015 to January 2018, 192 patients (mean age 63,1±15,9 years, M:F=118:74) undergoing EP procedures were enrolled in the study. US-guided approach to femoral vessels cannulation was used in all subjects by four untrained operators. Femoral vein and artery depths and diameters were measured in all patients. Unsuccessful attempts (UA) and time to successful cannulation (TSC) were also calculated. Results: Vein and artery depths correlated with body weight (r=0.38 and 0.39, p=0.00), body mass index (r=0.53 and 0.50, p=0.00), and body surface area (r=0.25 and 0.28, p=0.00). Interestingly, the number of UA positively correlated with vein depth (r=0.23, p=0.01 for the right side and r=0.33, p=0.00 for the left side). Linear regression analysis showed that both vein depth (ß=0.42, p=0.001) andoperator training (ß=-0.75,p=0.00) were independently associated with UA. Conclusions: Anthropometric features, namely BMI and BSA, may provide information about femoral vein/artery anatomy in patients undergoing EP procedures. Patients with high BMI have deeper and larger veins, however only vein depth is a determinant of successful cannulation. Numbers of UA and TSC significantly decrease with operators training.| File | Dimensione | Formato | |
|---|---|---|---|
|
66_Predictors of Successful Ultrasound Guided Femoral Vein Cannulation.pdf
solo utenti autorizzati
Descrizione: Predictors of Successful Ultrasound Guided Femoral Vein Cannulation in Electrophysiological Procedures
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
866 kB
Formato
Adobe PDF
|
866 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


