COSINUS will be among the first underground experiments to operate Transition Edge Sensors in a dry dilution refrigerator, measuring temperature changes on the order of μK. A pulse tube cryocooler is used to cool down to 3K, trading simplified handling, by not using liquid noble gases, for an increased vibration noise level in the acoustic frequency range. As the signals measured with a TES are in the same frequency region, it is necessary to decouple the detectors from all possible noise sources. In COSINUS, a two-level passive decoupling system was developed and tested using piezo-based accelerometers. At the first level, the refrigerator is mechanically isolated from all external noise sources. For the second level an internal spring-based system was developed and tested on a mockup system. On the first level a reduction of the vibrational background up to a factor 4 below 10 Hz could be measured. On the second level a resonance frequency of 1.2 Hz with damping of higher frequencies was achieved.

A Vibration Decoupling System for TES Operation in the COSINUS Dry Dilution Refrigerator

Profeta G.;Tresca C.;
2024

Abstract

COSINUS will be among the first underground experiments to operate Transition Edge Sensors in a dry dilution refrigerator, measuring temperature changes on the order of μK. A pulse tube cryocooler is used to cool down to 3K, trading simplified handling, by not using liquid noble gases, for an increased vibration noise level in the acoustic frequency range. As the signals measured with a TES are in the same frequency region, it is necessary to decouple the detectors from all possible noise sources. In COSINUS, a two-level passive decoupling system was developed and tested using piezo-based accelerometers. At the first level, the refrigerator is mechanically isolated from all external noise sources. For the second level an internal spring-based system was developed and tested on a mockup system. On the first level a reduction of the vibrational background up to a factor 4 below 10 Hz could be measured. On the second level a resonance frequency of 1.2 Hz with damping of higher frequencies was achieved.
2024
Istituto Superconduttori, materiali innovativi e dispositivi - SPIN - Sede Secondaria L'Aquila
Dark matter
Dry dilution refrigerator
Mechanical oscillator
TES
Vibration isolation
File in questo prodotto:
File Dimensione Formato  
2024_s10909-024-03206-x.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.28 MB
Formato Adobe PDF
1.28 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/513588
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact