Reinforced concrete (RC) structures built before the 1970 represent a large portion of the existing European buildings stock. Their obsolescence in terms of design criteria, materials, and functionality is becoming a critical issue for guaranteeing adequate compliance with current structural codes. Recently, a new jacketing system based on the use of high-performance fiber-reinforced concrete (HPFRC) has been introduced for strengthening existing RC building members. Despite the promising aspects of the HPFRC jacketing technique, currently, a comprehensive and systematic technical framework for its implementation is still missing. In this paper, the experimental performance of RC columns strengthened with the HPFRC jacket subjected to pure axial load and combined axial load-bending moment uncoupled from shear is investigated. The test outcomes confirmed a significant improvement of the structural performance for the strengthened columns, especially for higher values of eccentricity. Finally, a standard-based practice-oriented analytical tool for designing retrofit interventions using the HPFRC jacket is proposed. The comparison between the calculated and experimental results revealed a satisfactory prediction capability.

Experimental behavior of existing RC columns strengthened with HPFRC jacket under concentric and eccentric compressive load

Cassese P.;Occhiuzzi A.;
2021

Abstract

Reinforced concrete (RC) structures built before the 1970 represent a large portion of the existing European buildings stock. Their obsolescence in terms of design criteria, materials, and functionality is becoming a critical issue for guaranteeing adequate compliance with current structural codes. Recently, a new jacketing system based on the use of high-performance fiber-reinforced concrete (HPFRC) has been introduced for strengthening existing RC building members. Despite the promising aspects of the HPFRC jacketing technique, currently, a comprehensive and systematic technical framework for its implementation is still missing. In this paper, the experimental performance of RC columns strengthened with the HPFRC jacket subjected to pure axial load and combined axial load-bending moment uncoupled from shear is investigated. The test outcomes confirmed a significant improvement of the structural performance for the strengthened columns, especially for higher values of eccentricity. Finally, a standard-based practice-oriented analytical tool for designing retrofit interventions using the HPFRC jacket is proposed. The comparison between the calculated and experimental results revealed a satisfactory prediction capability.
2021
Istituto per le Tecnologie della Costruzione - ITC - Sede Secondaria Napoli
high-performance fiber-reinforced concrete; jacketing; experimental tests; axial load; retrofitting design
File in questo prodotto:
File Dimensione Formato  
buildings-11-00521-v2.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 5.55 MB
Formato Adobe PDF
5.55 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/513848
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact