Knee and hip arthroplasty represent common procedure in ortho paedics. However, the interaction between bone and implant need to be analysed. It has been well established that the bone around implant might be face to a decreased BMD mainly due to mechanical stress (i.e., stress shielding) of altered joint biomechanics and/or aseptic inflammatory reaction leading to periprosthetic bone resorption. For these reasons, monitoring the bone around an implant is mandatory to guarantee longevity of implant and rule out cause of pain. In recent years, the non-ionising REMS technology, through the analysis of the reference axial sites (lumbar spine and femoral neck), has been used to assess the bone health status and fracture risk prediction. However, REMSisable to analyse the bone health status even in the presence of prosthetic implants due to its capability to automatically discard artefacts. We report a clinical case of patient underwent to hip arthroplasty with the analysis of bilateral bone femoral neck through REMS technology.

RADIOFREQUENCY ECHOGRAPHIC MULTISPECTROMETRY (REMS) FOR THE ASSESSMENT OF BMD REDUCTION AFTER PROSTHETIC SURGERY: A CLINICAL CASE REPORT

F. A. Lombardi;P. Pisani;F. Conversano;E. Casciaro;C. Stomaci;S. Casciaro
2024

Abstract

Knee and hip arthroplasty represent common procedure in ortho paedics. However, the interaction between bone and implant need to be analysed. It has been well established that the bone around implant might be face to a decreased BMD mainly due to mechanical stress (i.e., stress shielding) of altered joint biomechanics and/or aseptic inflammatory reaction leading to periprosthetic bone resorption. For these reasons, monitoring the bone around an implant is mandatory to guarantee longevity of implant and rule out cause of pain. In recent years, the non-ionising REMS technology, through the analysis of the reference axial sites (lumbar spine and femoral neck), has been used to assess the bone health status and fracture risk prediction. However, REMSisable to analyse the bone health status even in the presence of prosthetic implants due to its capability to automatically discard artefacts. We report a clinical case of patient underwent to hip arthroplasty with the analysis of bilateral bone femoral neck through REMS technology.
2024
Istituto di Fisiologia Clinica - IFC - Sede Secondaria di Lecce
RADIOFREQUENCY, REMS, BMD REDUCTION, PROSTHETIC SURGERY
File in questo prodotto:
File Dimensione Formato  
2024ESCEO_807_REMS_prostetic_case.pdf

accesso aperto

Descrizione: RADIOFREQUENCY ECHOGRAPHIC MULTI SPECTROMETRY (REMS) FOR THE ASSESSMENT OF BMD REDUCTION AFTER PROSTHETIC SURGERY: A CLINICAL CASE REPORT
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 32.06 kB
Formato Adobe PDF
32.06 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/514854
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact