Background: To date, no standardized protocols nor a quantitative assessment of the near-infrared fluorescence angiography with indocyanine green (NIR-ICG) are available. The aim of this study was to evaluate the timing of fluorescence as a reproducible parameter and its efficacy in predicting anastomotic leakage (AL) in colorectal surgery. Methods: A consecutive cohort of 108 patients undergoing minimally invasive elective procedures for colorectal cancer was prospectively enrolled. The difference between macro and microperfusion (ΔT) was obtained by calculating the timing of fluorescence at the level of iliac artery division and colonic wall, respectively. Results: Subjects with a ΔT ≥ 15.5± 0.5 s had a higher tendency to develop an AL (p < 0.01). The ΔT/heart rate interaction was found to predict AL with an odds ratio of 1.02 (p < 0.01); a cut-off threshold of 832 was identified (sensitivity 0.86, specificity 0.77). Perfusion parameters were also associated with a faster bowel motility resumption and a reduced length of hospital stay. Conclusions: The analysis of the timing of fluorescence provides a quantitative, easy evaluation of tissue perfusion. A ΔT/HR interaction ≥832 may be used as a real-time parameter to guide surgical decision making in colorectal surgery.

NIR ICG-Enhanced Fluorescence: A Quantitative Evaluation of Bowel Microperfusion and Its Relation to Central Perfusion in Colorectal Surgery

Forciniti S.;del Mercato L. L.;
2023

Abstract

Background: To date, no standardized protocols nor a quantitative assessment of the near-infrared fluorescence angiography with indocyanine green (NIR-ICG) are available. The aim of this study was to evaluate the timing of fluorescence as a reproducible parameter and its efficacy in predicting anastomotic leakage (AL) in colorectal surgery. Methods: A consecutive cohort of 108 patients undergoing minimally invasive elective procedures for colorectal cancer was prospectively enrolled. The difference between macro and microperfusion (ΔT) was obtained by calculating the timing of fluorescence at the level of iliac artery division and colonic wall, respectively. Results: Subjects with a ΔT ≥ 15.5± 0.5 s had a higher tendency to develop an AL (p < 0.01). The ΔT/heart rate interaction was found to predict AL with an odds ratio of 1.02 (p < 0.01); a cut-off threshold of 832 was identified (sensitivity 0.86, specificity 0.77). Perfusion parameters were also associated with a faster bowel motility resumption and a reduced length of hospital stay. Conclusions: The analysis of the timing of fluorescence provides a quantitative, easy evaluation of tissue perfusion. A ΔT/HR interaction ≥832 may be used as a real-time parameter to guide surgical decision making in colorectal surgery.
2023
Istituto di Nanotecnologia - NANOTEC - Sede Lecce
anastomotic leakage
colorectal cancer
minimally invasive colorectal surgery
NIR-ICG-enhanced fluorescence
File in questo prodotto:
File Dimensione Formato  
cancers-15-05528.pdf

accesso aperto

Licenza: Altro tipo di licenza
Dimensione 2.62 MB
Formato Adobe PDF
2.62 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/516111
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact