A high-temperature rheometer equipped with a graphite furnace, characterized by an air-bearing-supported synchronous motor, has been enhanced by a custom-made Pt-Au concentric cylinder assembly. With this adaptation, viscosity measurements of highly fluid melts can be achieved at high temperatures, up to 1273 K. Due to the air-bearing-supported motor, this apparatus can perform measurements of extremely low torque ranging between 0.01 μNm and 230 mNm (resolution of 0.1 nNm), extending the typical range of viscosity measurements accessible in the present configuration to 10-3.5-103.5Pa.s and shear rates up to 102of s-1. We calibrated the system with distilled water, silicone oils, and the DGG-1 standard glass. We further present new data for the viscosity of Na2CO3, K2CO3, and Li2CO3 liquids. Finally, a comparison between our results and literature data is provided, to illustrate the effect of chemical composition and oxygen fugacity on the viscosity of alkali carbonate melts, which serve as analogs for both carbonatitic melts and molten carbonates of industrial relevance. This study substantially improves the database of alkali carbonate melts and dramatically increases the accuracy with respect to previous measurement attempts. The very low viscosity range data and their temperature dependence also helps to constrain very well the activation energy of these highly fluid systems and confirms the estimate of a universal pre-exponential factor for non-Arrhenian visco sity-temperature relationships.

An advanced rotational rheometer system for extremely fluid liquids up to 1273 K and applications to alkali carbonate melts

Di Genova D.
Primo
Conceptualization
;
2016

Abstract

A high-temperature rheometer equipped with a graphite furnace, characterized by an air-bearing-supported synchronous motor, has been enhanced by a custom-made Pt-Au concentric cylinder assembly. With this adaptation, viscosity measurements of highly fluid melts can be achieved at high temperatures, up to 1273 K. Due to the air-bearing-supported motor, this apparatus can perform measurements of extremely low torque ranging between 0.01 μNm and 230 mNm (resolution of 0.1 nNm), extending the typical range of viscosity measurements accessible in the present configuration to 10-3.5-103.5Pa.s and shear rates up to 102of s-1. We calibrated the system with distilled water, silicone oils, and the DGG-1 standard glass. We further present new data for the viscosity of Na2CO3, K2CO3, and Li2CO3 liquids. Finally, a comparison between our results and literature data is provided, to illustrate the effect of chemical composition and oxygen fugacity on the viscosity of alkali carbonate melts, which serve as analogs for both carbonatitic melts and molten carbonates of industrial relevance. This study substantially improves the database of alkali carbonate melts and dramatically increases the accuracy with respect to previous measurement attempts. The very low viscosity range data and their temperature dependence also helps to constrain very well the activation energy of these highly fluid systems and confirms the estimate of a universal pre-exponential factor for non-Arrhenian visco sity-temperature relationships.
2016
Istituto di Scienza, Tecnologia e Sostenibilità per lo Sviluppo dei Materiali Ceramici - ISSMC (ex ISTEC)
alkali carbonate melts
carbonatite
high-temperature rheometry
highly fluid melts
MCFCs
molten carbonate fuel cells
Viscosity
File in questo prodotto:
File Dimensione Formato  
15_5537GenovaOApc.pdf

accesso aperto

Descrizione: Articolo
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.01 MB
Formato Adobe PDF
1.01 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/518230
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? ND
social impact