The novel configuration presented in this work simplifies the layout of ejector-supported booster systems while maintaining all the benefits of an ejector implementation. The basic version of the solution is based on: i) MT and LT compressor suction groups, ii) flooded MT evaporation with increased evaporation temperature, and iii) ejector utilization throughout the year. The ejector is actively operated as a high-pressure-control device at elevated ambient temperatures ('summer mode'). With lower ambient temperatures the ejector is operated passively, and the high-pressure control is performed by individual metering devices upstream of the different evaporators ('winter mode'). The feasibility tests performed in the laboratory proved that energy-wise this novel system configuration outperforms traditional and parallel compression supported booster systems under any condition. The pressure lift measured with active ejector is sufficient for liquid refrigerant distribution to the evaporators, while the pressure drop recorded in passive mode is negligible for practical applications.

Ejector for the world: simplified ejector-supported CO2 refrigeration systems for all climates

Francesco FABRIS;
2022

Abstract

The novel configuration presented in this work simplifies the layout of ejector-supported booster systems while maintaining all the benefits of an ejector implementation. The basic version of the solution is based on: i) MT and LT compressor suction groups, ii) flooded MT evaporation with increased evaporation temperature, and iii) ejector utilization throughout the year. The ejector is actively operated as a high-pressure-control device at elevated ambient temperatures ('summer mode'). With lower ambient temperatures the ejector is operated passively, and the high-pressure control is performed by individual metering devices upstream of the different evaporators ('winter mode'). The feasibility tests performed in the laboratory proved that energy-wise this novel system configuration outperforms traditional and parallel compression supported booster systems under any condition. The pressure lift measured with active ejector is sufficient for liquid refrigerant distribution to the evaporators, while the pressure drop recorded in passive mode is negligible for practical applications.
2022
Istituto per le Tecnologie della Costruzione - ITC - Sede Secondaria Padova
Refrigeration, Carbon Dioxide, R744, Ejector, Energy Efficiency, Simplicity
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/518835
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ente

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact