Deterministic lateral displacement (DLD) is a hydrodynamic method known for its high-resolution sorting of particles. It achieves this through a periodic array of obstacles and laminar flow that passively directs particles along in two different directions depending on the particles’ diameter. Many prior publications have been dedicated to the structural and geometrical development of DLD arrays to improve separation performance; however, a successful separation requires much more than a well-designed array. This paper shows how separation performance is affected by process parameters. For this purpose, the design and fabrication of a DLD device are described. Then three experiments show how process parameters affect the performance of the device. The first experiment uses dye solutions to visualize the formation of a hydrodynamically focused sample stream. The second experiment shows that the particle separation performance (of 7- & 15-µm particles) is affected by the way output fluids are collected. Finally, the third experiment looks at the particle separation efficiency as the input flow rates and the ratio of buffer to sample are changed. The results show that the proper range for buffer and sample flow rate in this device is 1–10 and 0.1–1 (µl/min), respectively. The buffer to sample flow rate ratio of 10 gives the highest separation efficiency, but at a lower sample throughput. The optimized values are specific for our device but demonstrate processes that we believe are universal for DLD separations.
Effect of process parameters on separation efficiency in a deterministic lateral displacement device
Marasso S. L.Ultimo
Supervision
2022
Abstract
Deterministic lateral displacement (DLD) is a hydrodynamic method known for its high-resolution sorting of particles. It achieves this through a periodic array of obstacles and laminar flow that passively directs particles along in two different directions depending on the particles’ diameter. Many prior publications have been dedicated to the structural and geometrical development of DLD arrays to improve separation performance; however, a successful separation requires much more than a well-designed array. This paper shows how separation performance is affected by process parameters. For this purpose, the design and fabrication of a DLD device are described. Then three experiments show how process parameters affect the performance of the device. The first experiment uses dye solutions to visualize the formation of a hydrodynamically focused sample stream. The second experiment shows that the particle separation performance (of 7- & 15-µm particles) is affected by the way output fluids are collected. Finally, the third experiment looks at the particle separation efficiency as the input flow rates and the ratio of buffer to sample are changed. The results show that the proper range for buffer and sample flow rate in this device is 1–10 and 0.1–1 (µl/min), respectively. The buffer to sample flow rate ratio of 10 gives the highest separation efficiency, but at a lower sample throughput. The optimized values are specific for our device but demonstrate processes that we believe are universal for DLD separations.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.