In Deuterium Plasmas differences were detected in JET between electron temperature measurements (Te) made by Electron Cyclotron Emission - Te_ECE - and Thomson Scattering diagnostics systems (Te_TS) [1]. Similar behaviour was found in TFTR [2]. Plasmas heated by ECRH (Electron Cyclotron Heating) in Deuterium on FTU showed T_ECE < T_TS for 8 KeV ≤ Te ≤ 14 keV [3]. These differences can be due to the non-Maxwellian nature of the Electron velocity Distribution Function (EDF) [5,6]. The radiation temperature (Trad) measured by ECE is equal to the Te only for a Maxwellian plasma: being Trad dependent on the derivative of the EDF with respect to perpendicular velocity [5]. This paper describes differences of Te measured by ECE (ECE_MP, Martin-Puplett interferometer) and High-Resolution Thomson Scattering (HRTS) diagnostic. HRTS gives independent information on these differences, having shorter space resolution (2 cm), and faster repetition rate (20 Hz) on a different line of sight (16 cm from the magnetic centre): HRTS measurements confirm the trends observed using LIDAR TS [4,5]. Comparison between HRTS and ECE radiometer measurements is also reported (see sec.3).

Study on Differences of ECE and High-Resolution Thomson Scattering temperature measurements in DT (Deuterium-Tritium) plasmas on JET

Orsitto F. P.;Senni L.;Figini L.;Schmuck S.;Sozzi C.;
2023

Abstract

In Deuterium Plasmas differences were detected in JET between electron temperature measurements (Te) made by Electron Cyclotron Emission - Te_ECE - and Thomson Scattering diagnostics systems (Te_TS) [1]. Similar behaviour was found in TFTR [2]. Plasmas heated by ECRH (Electron Cyclotron Heating) in Deuterium on FTU showed T_ECE < T_TS for 8 KeV ≤ Te ≤ 14 keV [3]. These differences can be due to the non-Maxwellian nature of the Electron velocity Distribution Function (EDF) [5,6]. The radiation temperature (Trad) measured by ECE is equal to the Te only for a Maxwellian plasma: being Trad dependent on the derivative of the EDF with respect to perpendicular velocity [5]. This paper describes differences of Te measured by ECE (ECE_MP, Martin-Puplett interferometer) and High-Resolution Thomson Scattering (HRTS) diagnostic. HRTS gives independent information on these differences, having shorter space resolution (2 cm), and faster repetition rate (20 Hz) on a different line of sight (16 cm from the magnetic centre): HRTS measurements confirm the trends observed using LIDAR TS [4,5]. Comparison between HRTS and ECE radiometer measurements is also reported (see sec.3).
2023
Istituto Applicazioni del Calcolo ''Mauro Picone''
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
ECE
Thomson Scattering
JET
Plasma Diagnostics
File in questo prodotto:
File Dimensione Formato  
2023_Orsitto_EPS_Proceedings_Mo_MCF19_Orsitto.pdf

solo utenti autorizzati

Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 14.49 MB
Formato Adobe PDF
14.49 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/520396
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact