In this work, two novel (-)-menthol-based hydrophobic natural eutectic solvents with vanillin and cinnamic acid were prepared and applied as extraction solvents. In this regard, 12 endocrine disruptors, including phenol, 2,4-dimethylphenol, 2,3,6- trimethylphenol, 4-tert-butylphenol, 4-sec-butylphenol, 4-tert-amylphenol, 4-n-hexylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-n-octylphenol, and 4-n-nonylphenol and bisphenol A, were studied in a green tea drink. A temperature-controlled liquid–liquid microextraction was used as the extraction method, and nano-liquid chromatography–ultraviolet detection was used as the separation and determination system. Different parameters affecting the compatibility of the non-ionic eutectic solvents with water-polar organic solvent mixtures and chromatographic and detection systems were optimized, including injection/dilution solvent, injection mode, mobile phase composition, and step gradient. With the same purpose, two stationary phases were tested, including XBridge® C₁₈ and a mixed-phase Cogent C₃₀-XBridge® C₁₈. Finally, the greenness and blueness of the methodology were assessed to evaluate the environmental profile and usability of the procedure.
Natural eutectic solvent-based temperature-controlled liquid–liquid microextraction and nano-liquid chromatography for the analysis of herbal aqueous samples
D'Orazio G.;
2025
Abstract
In this work, two novel (-)-menthol-based hydrophobic natural eutectic solvents with vanillin and cinnamic acid were prepared and applied as extraction solvents. In this regard, 12 endocrine disruptors, including phenol, 2,4-dimethylphenol, 2,3,6- trimethylphenol, 4-tert-butylphenol, 4-sec-butylphenol, 4-tert-amylphenol, 4-n-hexylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-n-octylphenol, and 4-n-nonylphenol and bisphenol A, were studied in a green tea drink. A temperature-controlled liquid–liquid microextraction was used as the extraction method, and nano-liquid chromatography–ultraviolet detection was used as the separation and determination system. Different parameters affecting the compatibility of the non-ionic eutectic solvents with water-polar organic solvent mixtures and chromatographic and detection systems were optimized, including injection/dilution solvent, injection mode, mobile phase composition, and step gradient. With the same purpose, two stationary phases were tested, including XBridge® C₁₈ and a mixed-phase Cogent C₃₀-XBridge® C₁₈. Finally, the greenness and blueness of the methodology were assessed to evaluate the environmental profile and usability of the procedure.| File | Dimensione | Formato | |
|---|---|---|---|
|
Foods 2025, 14, 28.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
3.86 MB
Formato
Adobe PDF
|
3.86 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


