Preliminary results on an electrosynthesized ion-imprinted polymeric (IIP) film for the development of a Co2+ sensor are reported herein. The sensor was prepared by CV electropolymerization of 2-aminophenol (2-AP) monomer in the presence of Co2+ ions, which acted as the template. The screen-printed carbon electrodes (SPCEs) were used as transducers during sensor development, whereas the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used for the electrochemical characterization of sensors and for Co2+ ion sensing, respectively. The CV (potential range −0.2 and 1.2 V) and EIS measurements were performed in PBS (pH 7.8 , 0.1 M) containing 0.1 mol L−1 KCl solution and 5.0 mmol L−1 of Fe(CN)63−/4− as the redox probe ; for EIS an open circuit and data were settled through a sinusoidal potential perturbation of 0.01 V amplitude and 57 as frequency values that were logarithmically distributed over a range of frequencies between 0.01 Hz and 100 kHz. A not imprinted polymer (NIP) was prepared as a control under the same protocol, but without adding the template into the polymerization mixture. In these preliminary tests, the electropolymerization patterns of IIP polymers were found to be consistent with the findings previously reported. After electropolymerization, rinsed electrodes were incubated in different Co2+ concentrations of ions to be tested through EIS showing a response in the range 1–8 μM. A multivariate optimization based on the design of experiment (DOE) was employed to study the effect of parameters on electrochemical performances of the sensor.

Development of Electrochemical Sensors Based on Electrosynthesized Imprinted Polymers for Cobalt + Ion (Co2+) Determination in Water

Sabrina Di Masi
;
2022

Abstract

Preliminary results on an electrosynthesized ion-imprinted polymeric (IIP) film for the development of a Co2+ sensor are reported herein. The sensor was prepared by CV electropolymerization of 2-aminophenol (2-AP) monomer in the presence of Co2+ ions, which acted as the template. The screen-printed carbon electrodes (SPCEs) were used as transducers during sensor development, whereas the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used for the electrochemical characterization of sensors and for Co2+ ion sensing, respectively. The CV (potential range −0.2 and 1.2 V) and EIS measurements were performed in PBS (pH 7.8 , 0.1 M) containing 0.1 mol L−1 KCl solution and 5.0 mmol L−1 of Fe(CN)63−/4− as the redox probe ; for EIS an open circuit and data were settled through a sinusoidal potential perturbation of 0.01 V amplitude and 57 as frequency values that were logarithmically distributed over a range of frequencies between 0.01 Hz and 100 kHz. A not imprinted polymer (NIP) was prepared as a control under the same protocol, but without adding the template into the polymerization mixture. In these preliminary tests, the electropolymerization patterns of IIP polymers were found to be consistent with the findings previously reported. After electropolymerization, rinsed electrodes were incubated in different Co2+ concentrations of ions to be tested through EIS showing a response in the range 1–8 μM. A multivariate optimization based on the design of experiment (DOE) was employed to study the effect of parameters on electrochemical performances of the sensor.
2022
Istituto di Nanotecnologia - NANOTEC - Sede Lecce
2-AP
electrochemical sensor
Co2+ ions
electropolymerization
ion-imprinted polymer
File in questo prodotto:
File Dimensione Formato  
engproc-16-00015.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 188.88 kB
Formato Adobe PDF
188.88 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/523947
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact