Cork laser induced graphene (cork-LIG) electrochemical sensors are fabricated by direct laser writing of natural cork sheets. Laser writing is performed with a hobbyist visible laser. The obtained cork-LIG structures display graphene-like Raman signatures, high conductivity, and fast electron-transfer rates. After a 10 min electrochemical pretreatment, electrodes are used for detection of Tyrosine (Tyr) in the presence of uric acid, dopamine, ascorbic acid, urea, and glucose. linear detection of tyrosine is achieved in the 5–150 µm range with a limit of detection (LOD) of 3.03 µm. Calibration of dopamine detection is achieved with a LOD of 1.1 µm. Finally, the cork-LIG electrochemical sensors show linear response of Tyr in artificial sweat in the relevant physiological range of 5–250 μm (sensitivity, 1.8×10−2 A m−1). The LOD is calculated as 3.75 μm. These results open the door to the exploitation of renewable materials such as cork for the development of high-quality, green sensors for the monitoring of health and wellbeing parameters.

Sustainable Laser‐Induced Graphene Electrochemical Sensors from Natural Cork for Sensitive Tyrosine Detection

Santillo, Chiara;Gentile, Gennaro;Lavorgna, Marino;
2023

Abstract

Cork laser induced graphene (cork-LIG) electrochemical sensors are fabricated by direct laser writing of natural cork sheets. Laser writing is performed with a hobbyist visible laser. The obtained cork-LIG structures display graphene-like Raman signatures, high conductivity, and fast electron-transfer rates. After a 10 min electrochemical pretreatment, electrodes are used for detection of Tyrosine (Tyr) in the presence of uric acid, dopamine, ascorbic acid, urea, and glucose. linear detection of tyrosine is achieved in the 5–150 µm range with a limit of detection (LOD) of 3.03 µm. Calibration of dopamine detection is achieved with a LOD of 1.1 µm. Finally, the cork-LIG electrochemical sensors show linear response of Tyr in artificial sweat in the relevant physiological range of 5–250 μm (sensitivity, 1.8×10−2 A m−1). The LOD is calculated as 3.75 μm. These results open the door to the exploitation of renewable materials such as cork for the development of high-quality, green sensors for the monitoring of health and wellbeing parameters.
2023
Istituto per i Polimeri, Compositi e Biomateriali - IPCB
Graphene, LIG, sensor
File in questo prodotto:
File Dimensione Formato  
Advanced Sensor Research - 2023 - Vaughan.pdf

accesso aperto

Licenza: Dominio pubblico
Dimensione 2.66 MB
Formato Adobe PDF
2.66 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/524700
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact