A main aspect of the geothermal well design is the selection of grouts backfilling the space between a geothermal probe and the surrounding ground, taking into consideration the mineralogical, thermo–physical, mechanical and flowability properties. The EU GEO4CIVHIC project aimed at developing efficient and cost-effective geothermal systems suitable for the air-conditioning refurbishment of urban buildings. A selection of different grouts was performed to ensure the whole efficiency of shallow geothermal heat exchangers designed within the project. Experimental tests were executed to identify flowable grouts with the best possible combination of different material properties, while also fulfilling a competitive cost target set forth in the preliminary project cost analysis. Grout acceptance criteria were defined: a working time of at least 4 h, a water bleeding target of 2% and a volumetric shrinkage upper bound of 4%, a thermal conductivity in water saturated conditions of at least 1.4 to 1.5 Wm−1K−1, a compressive strength range of 1 to 2.1 MPa, a flow time range of 60 ± 15 s. Two out of six commercial grouts were selected for installations onsite.

Selection of backfill grout for shallow geothermal systems: Materials investigation and thermo-physical analysis

Garbin, Enrico;Bernardi, Adriana;
2022

Abstract

A main aspect of the geothermal well design is the selection of grouts backfilling the space between a geothermal probe and the surrounding ground, taking into consideration the mineralogical, thermo–physical, mechanical and flowability properties. The EU GEO4CIVHIC project aimed at developing efficient and cost-effective geothermal systems suitable for the air-conditioning refurbishment of urban buildings. A selection of different grouts was performed to ensure the whole efficiency of shallow geothermal heat exchangers designed within the project. Experimental tests were executed to identify flowable grouts with the best possible combination of different material properties, while also fulfilling a competitive cost target set forth in the preliminary project cost analysis. Grout acceptance criteria were defined: a working time of at least 4 h, a water bleeding target of 2% and a volumetric shrinkage upper bound of 4%, a thermal conductivity in water saturated conditions of at least 1.4 to 1.5 Wm−1K−1, a compressive strength range of 1 to 2.1 MPa, a flow time range of 60 ± 15 s. Two out of six commercial grouts were selected for installations onsite.
2022
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
Istituto di Scienze dell'Atmosfera e del Clima - ISAC
Shallow geothermal systems, Backfill grouts, Borehole heat exchangers, Thermo–physical properties, Grout flowability
File in questo prodotto:
File Dimensione Formato  
2022 - Mascarin et al - Selection of backgfill grout for...[Enrico].pdf

accesso aperto

Descrizione: Paper
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 4.68 MB
Formato Adobe PDF
4.68 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/525527
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
social impact