Monitoring the mechanical performances of a foot prosthesis is important to early identify possible changes that could affect patient health over time. This work aims to evaluate the feasibility of implementing such monitoring using Fiber Bragg Gratings (FBG) based sensing system. A single optical fiber equipped with 5 FBGs was glued on a 3D-printed foot prosthesis. The design of the prosthesis and the location of FBG sensors were optimized through Finite Element Simulations. The instrumented prosthesis was tested following ISO standards designed to access its mechanical parameters. Quasi-static tests simulating different gait phases were carried out to estimate the relationship between applied force and strain; cyclic tests were performed to evaluate any potential damage condition. The proposed sensing system based on FBGs was able to detect the plastic deformation of the material and the failure condition of the prosthesis. These results further corroborate the importance of equipping a prosthetic foot with a dedicated monitoring system.

Measurement of Strain on 3D-Printed Foot Prosthesis Using Fiber Bragg Grating Sensors

Rollo Gennaro;Romano' Jacopo;Garavaglia Lorenzo;Lavorgna Marino;Sorrentino Andrea;Pittaccio Simone;
2024

Abstract

Monitoring the mechanical performances of a foot prosthesis is important to early identify possible changes that could affect patient health over time. This work aims to evaluate the feasibility of implementing such monitoring using Fiber Bragg Gratings (FBG) based sensing system. A single optical fiber equipped with 5 FBGs was glued on a 3D-printed foot prosthesis. The design of the prosthesis and the location of FBG sensors were optimized through Finite Element Simulations. The instrumented prosthesis was tested following ISO standards designed to access its mechanical parameters. Quasi-static tests simulating different gait phases were carried out to estimate the relationship between applied force and strain; cyclic tests were performed to evaluate any potential damage condition. The proposed sensing system based on FBGs was able to detect the plastic deformation of the material and the failure condition of the prosthesis. These results further corroborate the importance of equipping a prosthetic foot with a dedicated monitoring system.
2024
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia (ICMATE) - Sede Secondaria Lecco
Istituto per i Polimeri, Compositi e Biomateriali - IPCB - Sede Secondaria di Lecco
monitoring
foot prosthesis
mechanical behavior
performance evaluation
FBG sensors
File in questo prodotto:
File Dimensione Formato  
Measurement of strain on 3D-printed foot prosthesis_compressed.pdf

solo utenti autorizzati

Descrizione: Accepted manuscript
Tipologia: Documento in Post-print
Licenza: Altro tipo di licenza
Dimensione 497.09 kB
Formato Adobe PDF
497.09 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/526202
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact