Objective: The objective of this work was to investigate technical validation and usability of an innovative, technically simple, easy-to-use, and portable integrated system to assess carotid function and structure by ultrasound. Methods: The studied system integrated a hardware (the Interson SP-L01 embedded ultrasound probe [Interson, Pleasanton, CA, USA]) and a software measuring the instantaneous diameter of the carotid artery in real-time from B-mode ultrasound image sequences (Carotid Studio, by Quipu Srl [Pisa, Italy]). Technical validation was evaluated by intra-operator reproducibility of two measurements acquired by an expert operator, and agreement with state-of-the-art technique (Mylab25 by Esaote SpA [Genova, Italy], Carotid Studio 4.3 by Quipu Srl) was evaluated in laboratory settings in 12 healthy volunteers; usability of the portable integrated system was investigated by administering questionnaires to users and the results were reported with scores based on a five-point scale. Results: Twelve (12) healthy volunteers (five men, mean age 44.5±13.6 years, free of cardiovascular disease or risk factors), were recruited. Agreement with state-of-the-art technique was satisfactory, with no significant bias. Coefficient of variation (intra-operator reproducibility) was 3.2% (2.5% SD) for intima-media thickness, 0.9% (0.7% SD) for diameter, and 2.5% (2.2% SD) for distension. Usability questionnaires showed an overall positive judgement of the integrated system with respect to the traditional one, obtaining an average score greater than 4 (on a five-point scale). Conclusions: A portable, innovative prototype to easily assess ultrasound carotid parameters of vascular ageing was successfully designed, developed, and demonstrated to be comparable with state-of-the art technique. Usability was also satisfactory.

Technical Validation and Usability of a Portable Ultrasound-Based System for Carotid Assessment of Vascular Ageing: A Pilot Study

Francesconi M.
Primo
;
Di Franco G.;Gemignani V.;Bianchini E.
;
Bruno R. M.
2021

Abstract

Objective: The objective of this work was to investigate technical validation and usability of an innovative, technically simple, easy-to-use, and portable integrated system to assess carotid function and structure by ultrasound. Methods: The studied system integrated a hardware (the Interson SP-L01 embedded ultrasound probe [Interson, Pleasanton, CA, USA]) and a software measuring the instantaneous diameter of the carotid artery in real-time from B-mode ultrasound image sequences (Carotid Studio, by Quipu Srl [Pisa, Italy]). Technical validation was evaluated by intra-operator reproducibility of two measurements acquired by an expert operator, and agreement with state-of-the-art technique (Mylab25 by Esaote SpA [Genova, Italy], Carotid Studio 4.3 by Quipu Srl) was evaluated in laboratory settings in 12 healthy volunteers; usability of the portable integrated system was investigated by administering questionnaires to users and the results were reported with scores based on a five-point scale. Results: Twelve (12) healthy volunteers (five men, mean age 44.5±13.6 years, free of cardiovascular disease or risk factors), were recruited. Agreement with state-of-the-art technique was satisfactory, with no significant bias. Coefficient of variation (intra-operator reproducibility) was 3.2% (2.5% SD) for intima-media thickness, 0.9% (0.7% SD) for diameter, and 2.5% (2.2% SD) for distension. Usability questionnaires showed an overall positive judgement of the integrated system with respect to the traditional one, obtaining an average score greater than 4 (on a five-point scale). Conclusions: A portable, innovative prototype to easily assess ultrasound carotid parameters of vascular ageing was successfully designed, developed, and demonstrated to be comparable with state-of-the art technique. Usability was also satisfactory.
2021
Istituto di Fisiologia Clinica - IFC
Carotid distensibility
Carotid IMT
Portable system
Ultrasound
File in questo prodotto:
File Dimensione Formato  
2021 Heart Lung Circulation.pdf

accesso aperto

Descrizione: Technical Validation and Usability of a Portable Ultrasound-Based System for Carotid Assessment of Vascular Ageing: A Pilot Study
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.28 MB
Formato Adobe PDF
1.28 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/527189
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact