The impedance of a rectangular electrode coated by a resistive film is calculated for the cases of linear and exponential thickness profiles along the electrode length. The local film capacity and local film resistance of each surface element are assumed to be inversely and directly proportional to local film thickness, respectively. Experimental model electrodes are prepared by anodizing niobium or tantalum rectangular sheets with a setup allowing the progressive extraction of the electrode from the electrolyte, at a constant rate, while the cell voltage is increased according to a suitable program. The impedance of the coated electrode, measured at a potential close to the lowest anodization potential, agrees well with theory. In particular, the plot of the ohmic resistance corrected phase angle vs frequency shows a minimum. The effect of experimental parameters such as thickness profile or solution concentration can be interpreted on the basis of the calculations.

Electrodes Coated by Passive Oxide Films with a Thickness Profile: Modeling and Measurement

S Cattarin;N Comisso;M Musiani;
2008

Abstract

The impedance of a rectangular electrode coated by a resistive film is calculated for the cases of linear and exponential thickness profiles along the electrode length. The local film capacity and local film resistance of each surface element are assumed to be inversely and directly proportional to local film thickness, respectively. Experimental model electrodes are prepared by anodizing niobium or tantalum rectangular sheets with a setup allowing the progressive extraction of the electrode from the electrolyte, at a constant rate, while the cell voltage is increased according to a suitable program. The impedance of the coated electrode, measured at a potential close to the lowest anodization potential, agrees well with theory. In particular, the plot of the ohmic resistance corrected phase angle vs frequency shows a minimum. The effect of experimental parameters such as thickness profile or solution concentration can be interpreted on the basis of the calculations.
2008
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
anodisation
coatings
electric impedance measurement
electric resistance
File in questo prodotto:
File Dimensione Formato  
prod_21644-doc_10179.pdf

non disponibili

Descrizione: Electrodes Coated by Passive Oxide Films with a Thickness Profile: Modeling and Measurement
Dimensione 335.24 kB
Formato Adobe PDF
335.24 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/53026
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact