Adsorption and detection of environmental total gaseous mercury (TGM) was studied by using gold nanoparticles (AuNPs) on purpose functionalized with dithiol ligands, i.e. Biphenyl-4,4'-dithiol (BI) or p-Terphenyl-4,4 ''-dithiol (TR), suitable for nanoparticles based network formation. AuNPs-BI and AuNPs-TR with size 6-8 nm were deposited onto quartz fibres and used as adsorbent materials for the detection of TGM, both indoor for adsorption studies, at defined concentrations (similar to 4.5 ng m(-)(3) Hg), and outdoor, at the vapour mercury concentration of the environmental countryside (similar to 1.5 ng m(-3) Hg). The role of relative humidity (RH) in the absorption process has been observed. A high Hg adsorption capability, also when exposed to sub ppb concentration, has been observed. A cold vapour atomic fluorescence spectroscopy (CVAFS) detector was used to determine gaseous mercury concentrations lower than 2 ng m(-3), with a robust and reproducible procedure. Moreover, the use of quartz fibres substrate covered with AuNPs-BI or AuNPs-TR, and used for more than thirty times during the experiments, makes them competitive in the use in large-scale measurement campaigns.

Environmental Hg vapours adsorption and detection by using functionalized gold nanoparticles network

Bearzotti A.;Papa P.;Macagnano A.;Zampetti E.;Fontana L.;
2018

Abstract

Adsorption and detection of environmental total gaseous mercury (TGM) was studied by using gold nanoparticles (AuNPs) on purpose functionalized with dithiol ligands, i.e. Biphenyl-4,4'-dithiol (BI) or p-Terphenyl-4,4 ''-dithiol (TR), suitable for nanoparticles based network formation. AuNPs-BI and AuNPs-TR with size 6-8 nm were deposited onto quartz fibres and used as adsorbent materials for the detection of TGM, both indoor for adsorption studies, at defined concentrations (similar to 4.5 ng m(-)(3) Hg), and outdoor, at the vapour mercury concentration of the environmental countryside (similar to 1.5 ng m(-3) Hg). The role of relative humidity (RH) in the absorption process has been observed. A high Hg adsorption capability, also when exposed to sub ppb concentration, has been observed. A cold vapour atomic fluorescence spectroscopy (CVAFS) detector was used to determine gaseous mercury concentrations lower than 2 ng m(-3), with a robust and reproducible procedure. Moreover, the use of quartz fibres substrate covered with AuNPs-BI or AuNPs-TR, and used for more than thirty times during the experiments, makes them competitive in the use in large-scale measurement campaigns.
2018
Istituto sull'Inquinamento Atmosferico - IIA - Sede Secondaria Roma
Mercury vapour monitoring
Gold nanoparticles
Outdoor monitoring
Sensing device
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S2213343718303920-main.pdf

solo utenti autorizzati

Descrizione: Articolo
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.14 MB
Formato Adobe PDF
2.14 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/531041
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 22
social impact