The design of a compact 2 x 2 diamond matrix with independent and redundant pixels optimized for the spectrometric neutron camera of the SPARC tokamak is presented in this article. Such a matrix overcomes the constraints in dynamic range posed by the size of a single diamond sensor while keeping the ability to perform energy spectral analysis, marking a significant advancement in tokamak neutron diagnostics. A charge pre-amplifier based on radio frequency amplifiers based on InGaP technology transistors, offering up to 2 GHz bandwidth with high robustness against radiation, has been developed. A first single-channel device has been tested and proven to provide a fast signal development time of 20-25 ns, necessary to mitigate pileup effects while offering precise energy measurements. As the diamond sensors may suffer from polarization effects due to the trapping of charges at the diamond/metal interface, a periodical bias inversion can guarantee optimal performance. To facilitate that, a reversible high voltage power supply has been developed. The ongoing development of data acquisition equipment and real-time processing algorithms based on programmable gate arrays further enhances the neutron camera's capabilities.

Design studies on electronics and data acquisition of a real time diamond spectrometer for the SPARC neutron camera

Croci G.;Gorini G.;Nocente M.;Putignano O.;Rebai M.;Tardocchi M.;
2024

Abstract

The design of a compact 2 x 2 diamond matrix with independent and redundant pixels optimized for the spectrometric neutron camera of the SPARC tokamak is presented in this article. Such a matrix overcomes the constraints in dynamic range posed by the size of a single diamond sensor while keeping the ability to perform energy spectral analysis, marking a significant advancement in tokamak neutron diagnostics. A charge pre-amplifier based on radio frequency amplifiers based on InGaP technology transistors, offering up to 2 GHz bandwidth with high robustness against radiation, has been developed. A first single-channel device has been tested and proven to provide a fast signal development time of 20-25 ns, necessary to mitigate pileup effects while offering precise energy measurements. As the diamond sensors may suffer from polarization effects due to the trapping of charges at the diamond/metal interface, a periodical bias inversion can guarantee optimal performance. To facilitate that, a reversible high voltage power supply has been developed. The ongoing development of data acquisition equipment and real-time processing algorithms based on programmable gate arrays further enhances the neutron camera's capabilities.
2024
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Neutron
File in questo prodotto:
File Dimensione Formato  
Petruzzo_SPARC_2024.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Altro tipo di licenza
Dimensione 8.42 MB
Formato Adobe PDF
8.42 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/537635
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact