The X-IFU is one of the two instruments of ATHENA, the next ESA large X-ray observatory. It is a cryogenic spectrometer based on an array of TES microcalorimeters. To reduce the particle background, the TES array works in combination with a Cryogenic AntiCoincidence detector (CryoAC). The CryoAC is a 4-pixel detector, based on ~1 cm2 silicon absorbers sensed by Ir/Au TES. It is required to have a wide energy bandwidth (from 20 keV to ~1 MeV), high efficiency (< 0.014% missed particles), low dead-time (< 1%) and good time-tagging accuracy (10 μs at 1σ). An end-to-end simulator of the CryoAC detector has been developed both for design and performance assessment, consisting of several modules. First, the in-flight flux of background particles is evaluated by Geant4 simulations. Then, the current flow in the TES is evaluated by solving the electro-thermal equations of microcalorimeters, and the detector output signal is generated by simulating the SQUID FLL dynamics. Finally, the output is analyzed by a high-efficiency trigger algorithm, producing the simulated CryoAC telemetry. Here, we present in detail this end-to-end simulator, and how we are using it to define the new CryoAC baseline configuration in the new Athena context.

The end-to-end simulator of the ATHENA X-IFU Cryogenic AntiCoincidence detector (CryoAC)

Minervini G.;Torrioli G.;Chiarello F.;Gatti F.;
2024

Abstract

The X-IFU is one of the two instruments of ATHENA, the next ESA large X-ray observatory. It is a cryogenic spectrometer based on an array of TES microcalorimeters. To reduce the particle background, the TES array works in combination with a Cryogenic AntiCoincidence detector (CryoAC). The CryoAC is a 4-pixel detector, based on ~1 cm2 silicon absorbers sensed by Ir/Au TES. It is required to have a wide energy bandwidth (from 20 keV to ~1 MeV), high efficiency (< 0.014% missed particles), low dead-time (< 1%) and good time-tagging accuracy (10 μs at 1σ). An end-to-end simulator of the CryoAC detector has been developed both for design and performance assessment, consisting of several modules. First, the in-flight flux of background particles is evaluated by Geant4 simulations. Then, the current flow in the TES is evaluated by solving the electro-thermal equations of microcalorimeters, and the detector output signal is generated by simulating the SQUID FLL dynamics. Finally, the output is analyzed by a high-efficiency trigger algorithm, producing the simulated CryoAC telemetry. Here, we present in detail this end-to-end simulator, and how we are using it to define the new CryoAC baseline configuration in the new Athena context.
2024
Istituto di fotonica e nanotecnologie - IFN
ATHENA, X-IFU, CryoAC, Cryogenic detectors, Background, Anticoincidence, TES, SQUID, Trigger, Geant4
File in questo prodotto:
File Dimensione Formato  
2407.14083v1.pdf

accesso aperto

Tipologia: Documento in Pre-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.74 MB
Formato Adobe PDF
1.74 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/538199
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact