This prospective controlled clinical trial investigated the possible correlation among mucosa thickness, mucosa height, and width of keratinized mucosa on the contour changes of the peri-implant soft tissue collar over a period of 12 months. Forty patients were selected to undergo implant placement. Impressions were taken with polyether impression material at delivery of the final restorations (baseline) and at 1, 3, 6, and 12 months. Master casts were fabricated and scanned using an indirect digitalization. Baseline and corresponding follow-up scans were then virtually superimposed and matched. At 1 year, 20 patients who received the buccal pedicle flap showed an average thickness increase of 1.49 mm (ρs = 0.95; range: 0.01 to 2.56 mm), whereas the 5 patients who received a connective tissue graft at second-stage surgery reported an average thickness increase of 0.33 mm (ρs = 0.70; range: –0.62 to 1.23 mm). Finally, the remaining 15 patients who did not receive any soft tissue grafting nor any type of plastic surgery showed an average mucosa thickness increase of 0.51 mm (ρs = 0.28; range: –2.33 to 2.52 mm).

The Influence of Mucosa Thickness and Quality on Single Implant Tissue Stability: A Prospective Controlled Clinical Trial

Viale, Massimiliano
2021

Abstract

This prospective controlled clinical trial investigated the possible correlation among mucosa thickness, mucosa height, and width of keratinized mucosa on the contour changes of the peri-implant soft tissue collar over a period of 12 months. Forty patients were selected to undergo implant placement. Impressions were taken with polyether impression material at delivery of the final restorations (baseline) and at 1, 3, 6, and 12 months. Master casts were fabricated and scanned using an indirect digitalization. Baseline and corresponding follow-up scans were then virtually superimposed and matched. At 1 year, 20 patients who received the buccal pedicle flap showed an average thickness increase of 1.49 mm (ρs = 0.95; range: 0.01 to 2.56 mm), whereas the 5 patients who received a connective tissue graft at second-stage surgery reported an average thickness increase of 0.33 mm (ρs = 0.70; range: –0.62 to 1.23 mm). Finally, the remaining 15 patients who did not receive any soft tissue grafting nor any type of plastic surgery showed an average mucosa thickness increase of 0.51 mm (ρs = 0.28; range: –2.33 to 2.52 mm).
2021
Istituto dei Sistemi Complessi - ISC
Dental Implantation
Connective Tissue
File in questo prodotto:
File Dimensione Formato  
InfluenceMucosaImplantStability.pdf

solo utenti autorizzati

Descrizione: The Influence of Mucosa Thickness and Quality on Single Implant Tissue Stability: A Prospective Controlled Clinical Trial
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 776.87 kB
Formato Adobe PDF
776.87 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/538353
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact