This work presents the full set of 3D Computational Thermal-Fluid Dynamics (CFD) analyses of the Divertor Tokamak Test (DTT) Vacuum Vessel (VV). The VV D-shaped double shell structure, divided into 18 Regular and Special sectors, is actively maintained at the operating temperature of 60 °C by borated water in forced flow to counteract the thermal loads and the heat transfer with the surroundings. Due to manufacturing and integration constraints, the different sectors cannot share the same design: the water will flow in the free space between the two shells composing the VV but, given the complexity of the geometry, a careful hydraulic design is mandatory, to avoid local stagnation points which may cause either overheating or freezing. The different hydraulic paths are separately analysed with the Star-CCM+ software, with a SST turbulence closure, proving the effectiveness of their design (pressure drop, temperature constraints and stagnation/backflow). In addition, the borated water mass flow rate distribution among the different paths is assessed. To conclude, results from CFD analyses are exploited to approximate the hydraulic characteristic of each sector and to develop a system-level model of the full VV with the Modelica language. The overall VV pressure drop of 2810 Pa, the outlet mixing temperature of 333 K and a mass flow rate distribution close to the homogeneous condition (2.22 kg s−1 in each sector) confirm that no relevant issues are found in the current VV design from the thermal-hydraulic point of view.
Computational Thermal-Fluid Dynamics analyses of borated water distribution in the Vacuum Vessel of the Divertor Tokamak Test facility
Dalla Palma Mauro;
2024
Abstract
This work presents the full set of 3D Computational Thermal-Fluid Dynamics (CFD) analyses of the Divertor Tokamak Test (DTT) Vacuum Vessel (VV). The VV D-shaped double shell structure, divided into 18 Regular and Special sectors, is actively maintained at the operating temperature of 60 °C by borated water in forced flow to counteract the thermal loads and the heat transfer with the surroundings. Due to manufacturing and integration constraints, the different sectors cannot share the same design: the water will flow in the free space between the two shells composing the VV but, given the complexity of the geometry, a careful hydraulic design is mandatory, to avoid local stagnation points which may cause either overheating or freezing. The different hydraulic paths are separately analysed with the Star-CCM+ software, with a SST turbulence closure, proving the effectiveness of their design (pressure drop, temperature constraints and stagnation/backflow). In addition, the borated water mass flow rate distribution among the different paths is assessed. To conclude, results from CFD analyses are exploited to approximate the hydraulic characteristic of each sector and to develop a system-level model of the full VV with the Modelica language. The overall VV pressure drop of 2810 Pa, the outlet mixing temperature of 333 K and a mass flow rate distribution close to the homogeneous condition (2.22 kg s−1 in each sector) confirm that no relevant issues are found in the current VV design from the thermal-hydraulic point of view.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0920379624002680-main.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Nessuna licenza dichiarata (non attribuibile a prodotti successivi al 2023)
Dimensione
5.59 MB
Formato
Adobe PDF
|
5.59 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.