A multipurpose software, called Revolt, has been developed to fully exploit the imaging capabilities of Triple-GEM 2D cameras for X-rays and neutrons detection. Both tomographic inversion techniques and synthetic data production methods are based on the modeling of a transport matrix between the 2D spatially resolved signal on a detector and the 3D signal emission in the experimental space. The core task of the Revolt software is to provide a transport matrix between the two quantities via a numerical-geometrical approach. The method is based on the analytical evaluation of detector pixels Line Of Sight generated via a Monte Carlo method to include obstacle shading on the detector image. The Revolt implementation and validation are described in this work, which provides a solid base for future application of tomographic inversion techniques in the context of fusion plasma physics.

A multipurpose numerical method for imaging studies and tomographic reconstruction

Croci G.;Gorini G.;Grosso G.;Lazzaro E.;Marcer G.;Nocente M.;Putignano O.;Scionti J.;Tardocchi M.;Muraro A.
2024

Abstract

A multipurpose software, called Revolt, has been developed to fully exploit the imaging capabilities of Triple-GEM 2D cameras for X-rays and neutrons detection. Both tomographic inversion techniques and synthetic data production methods are based on the modeling of a transport matrix between the 2D spatially resolved signal on a detector and the 3D signal emission in the experimental space. The core task of the Revolt software is to provide a transport matrix between the two quantities via a numerical-geometrical approach. The method is based on the analytical evaluation of detector pixels Line Of Sight generated via a Monte Carlo method to include obstacle shading on the detector image. The Revolt implementation and validation are described in this work, which provides a solid base for future application of tomographic inversion techniques in the context of fusion plasma physics.
2024
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Computerized Tomography (CT) and Computed Radiography (CR), X-ray detectors; Electron multipliers (gas), Simulation methods and programs
File in questo prodotto:
File Dimensione Formato  
Celora_2024_J._Inst._19_C03032.pdf

accesso aperto

Licenza: Creative commons
Dimensione 1.01 MB
Formato Adobe PDF
1.01 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/539323
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact