In this work, an innovative system for structural health monitoring of metallic pipes is presented. The proposed system relies on exploiting the pipeline as a waveguide for the propagation of an electromagnetic (EM) signal. By analyzing the reflected signal, it is possible to assess the possible presence of anomalies or damage in the pipe.The innovative aspect of the proposed monitoring system is that the EM test signal is injected in the pipeline/waveguide through a coaxial/waveguide transition that is made on the surface of the pipe. In practical applications, this strategy would allow to connect more easily to operating, buried pipes.To characterize the propagation of the EM signal in such conditions and to verify the changes on the reflected signal provoked by variation of the conditions of the pipe, experimental tests were carried out and a dedicated processing strategy was developed. The obtained results, although preliminary, confirmed that the proposed method holds unexplored potential to be used as a structural health monitoring solution.

A new microwave method for on-site integrity monitoring of pipelines

Cannazza G.;
2020

Abstract

In this work, an innovative system for structural health monitoring of metallic pipes is presented. The proposed system relies on exploiting the pipeline as a waveguide for the propagation of an electromagnetic (EM) signal. By analyzing the reflected signal, it is possible to assess the possible presence of anomalies or damage in the pipe.The innovative aspect of the proposed monitoring system is that the EM test signal is injected in the pipeline/waveguide through a coaxial/waveguide transition that is made on the surface of the pipe. In practical applications, this strategy would allow to connect more easily to operating, buried pipes.To characterize the propagation of the EM signal in such conditions and to verify the changes on the reflected signal provoked by variation of the conditions of the pipe, experimental tests were carried out and a dedicated processing strategy was developed. The obtained results, although preliminary, confirmed that the proposed method holds unexplored potential to be used as a structural health monitoring solution.
2020
Istituto di Scienze del Patrimonio Culturale - ISPC - Sede Secondaria Lecce
9781728144603
Leak detection
Microwave monitoring
Pipelines
Reflectograms
Structural health monitoring
Waveguide
File in questo prodotto:
File Dimensione Formato  
A new microwave method for on-site integrity monitoring of pipelines.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.57 MB
Formato Adobe PDF
1.57 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/539761
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact