The Timed Up and Go (TUG) test is a widely recognized and standardized mobility test to measure basic mobility and balance capabilities. Despite the possibility to derive rich information about the patient, only the total time to complete the test is conventionally measured by a professional. This work examines the use of non-wearable sensors for the measurement of parameters of the test in an accurate and objective way. The study illustrates a system specifically designed for conducting the TUG test using a set of sensorized mats. The developed system is able to identify the following 4 phases of the test, with relative timestamps: TUG-time, Sit-to-Stand, Mid-Turning, and End-Turning-Stand-to-Sit. Additionally, meaningful parameters for gait assessment are also extracted: walking speed and stride length. Two experimental iterations were conducted to assess the reliability of the developed software. Both iterations involved two different groups of six healthy participants (41.58 ± 13.32 yrs; 6 females, 6 males) performing various walking types. Our results demonstrate that sensorized mats can be used to segment the phases of the test reliably and can additionally be used to quantify gait parameters during the walk phase of the test.

Objective characterization of timed up and go test via sensorized mats

Ghezzi D.
Methodology
;
La Rosa D.;Palumbo F.
2025

Abstract

The Timed Up and Go (TUG) test is a widely recognized and standardized mobility test to measure basic mobility and balance capabilities. Despite the possibility to derive rich information about the patient, only the total time to complete the test is conventionally measured by a professional. This work examines the use of non-wearable sensors for the measurement of parameters of the test in an accurate and objective way. The study illustrates a system specifically designed for conducting the TUG test using a set of sensorized mats. The developed system is able to identify the following 4 phases of the test, with relative timestamps: TUG-time, Sit-to-Stand, Mid-Turning, and End-Turning-Stand-to-Sit. Additionally, meaningful parameters for gait assessment are also extracted: walking speed and stride length. Two experimental iterations were conducted to assess the reliability of the developed software. Both iterations involved two different groups of six healthy participants (41.58 ± 13.32 yrs; 6 females, 6 males) performing various walking types. Our results demonstrate that sensorized mats can be used to segment the phases of the test reliably and can additionally be used to quantify gait parameters during the walk phase of the test.
2025
Istituto di Scienza e Tecnologie dell'Informazione "Alessandro Faedo" - ISTI
978-3-031-85574-0
Timed Up and Go, Gait Analysis, Pressure Sensor, Sensorized Mat
File in questo prodotto:
File Dimensione Formato  
Malisa_TUG.pdf

accesso aperto

Descrizione: Objective Characterization of Timed Up and Go Test via Sensorized Mats
Tipologia: Documento in Pre-print
Licenza: Altro tipo di licenza
Dimensione 2.1 MB
Formato Adobe PDF
2.1 MB Adobe PDF Visualizza/Apri
Ghezzi-La Rosa-Palumbo et al_LNICST 2025.pdf

solo utenti autorizzati

Descrizione: Objective Characterization of Timed Up and Go Test via Sensorized Mats
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.99 MB
Formato Adobe PDF
1.99 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/550830
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact