Many different devices are available to measure water content of soil but it is not evident that they work with the rocks too. The measurement of rock water content, especially in the field, is not easy for the difficulties in the installation of the probes ensuring the contact between the rock and the sensor. The Z-meter 2 device allow to use different kind of probes that are resistant enough to be installed into rocks. Experimental tests are carried out in laboratory in order to verify if the Z-meter 2 device could be used to measure the water content of the rock. One kind of probes have been installed on rock samples and are tested across a range of measurement frequencies between 100 to 10000 Hz using water with different electrical conductivity values. The experimentation was performed in environment with controlled temperature. Preliminary results reported show that the Z-meter 2 device work well in the calcarenite allowing the measurement of rock water content. The sensitivity of Z-meter 2 probes, to changing electrical conductivity, is high and it suggests to use a calibration curve for each narrow range of known electrical conductivity values of solution.

MEASUREMENTS OF ROCK WATER CONTENT WITH Z-METER 2 DEVICE

CAPUTO MC;DE BENEDICTIS F;MASCIALE R
2009

Abstract

Many different devices are available to measure water content of soil but it is not evident that they work with the rocks too. The measurement of rock water content, especially in the field, is not easy for the difficulties in the installation of the probes ensuring the contact between the rock and the sensor. The Z-meter 2 device allow to use different kind of probes that are resistant enough to be installed into rocks. Experimental tests are carried out in laboratory in order to verify if the Z-meter 2 device could be used to measure the water content of the rock. One kind of probes have been installed on rock samples and are tested across a range of measurement frequencies between 100 to 10000 Hz using water with different electrical conductivity values. The experimentation was performed in environment with controlled temperature. Preliminary results reported show that the Z-meter 2 device work well in the calcarenite allowing the measurement of rock water content. The sensitivity of Z-meter 2 probes, to changing electrical conductivity, is high and it suggests to use a calibration curve for each narrow range of known electrical conductivity values of solution.
2009
Istituto di Ricerca Sulle Acque - IRSA
Inglese
EUREKA 2009 - 5th Working session
5TH WORKING SESSION WITHIN THE FRAMEWORK OF THE INTERNATIONAL PROJECT EUREKA PROJECT NO.: E!3838
77
87
978-80-214-3969-6
http://www.eureka3838.com/index.php?option=com_content&view=article&id=44&Itemid=54&lang=en
Sì, ma tipo non specificato
11-13 November 2009
BRNO - SVRATKA (CZECH REPUBLIC
Rock water content
calibration
electrical impedance spectrometry
3
none
Caputo, Mc; DE BENEDICTIS, F; Masciale, R
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/55695
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact