This work presents an experimental on-field case-study analysis of Standards-based metrics for supraharmonics (SHs) measurements in distribution networks. IEC 61000-4-30 FFT-based metrics, with some proposed modifications, are compared with measurements according with CISPR 16-1-2, using as reference IEC 61000-2-2 and IEC 61000-2-4 for SHs emissions limits in 9-150 kHz frequency range. Measurements have been carried out on a commercial bidirectional power electronic converter (ac/dc and dc/ac) with a battery storage system, operating in both charging and discharging mode and with different power levels. To investigate the feasibility of the proposed approach, the analysis is extended to both voltage and current waveforms. The obtained results show that, with some modifications, IEC 61000-4-30 FFT-based metrics can provide information comparable with CISPR-based measurements, in the perspective of preliminary in-situ evaluation of SHs emissions levels and without the need of sophisticated on-field instrumentation.

Supraharmonics in-situ measurements in distribution networks. An experimental case-study analysis of Standards-based metrics

Cara, Dario Di;Ditta, Vito;Panzavecchia, Nicola;TINE', Giovanni
2025

Abstract

This work presents an experimental on-field case-study analysis of Standards-based metrics for supraharmonics (SHs) measurements in distribution networks. IEC 61000-4-30 FFT-based metrics, with some proposed modifications, are compared with measurements according with CISPR 16-1-2, using as reference IEC 61000-2-2 and IEC 61000-2-4 for SHs emissions limits in 9-150 kHz frequency range. Measurements have been carried out on a commercial bidirectional power electronic converter (ac/dc and dc/ac) with a battery storage system, operating in both charging and discharging mode and with different power levels. To investigate the feasibility of the proposed approach, the analysis is extended to both voltage and current waveforms. The obtained results show that, with some modifications, IEC 61000-4-30 FFT-based metrics can provide information comparable with CISPR-based measurements, in the perspective of preliminary in-situ evaluation of SHs emissions levels and without the need of sophisticated on-field instrumentation.
2025
Istituto di iNgegneria del Mare - INM (ex INSEAN) - Sede Secondaria Palermo
978-1-6654-7765-9
power system measurements
power electronic converters
converters
supraharmonics
power quality
File in questo prodotto:
File Dimensione Formato  
Supraharmonics_in-situ_measurements_in_distribution_networks._An_experimental_case-study_analysis_of_Standards-based_metrics.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 686.95 kB
Formato Adobe PDF
686.95 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/564881
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact