This study investigated the effect of a theranostic-guided UV-A light corneal photo-reshaping technique on corneal elevation and wavefront aberration (WA) in human donor eyes. A specialized platform, combining UV-A light with corneal iontophoresis for controlled, patterned, riboflavin delivery, was used for both distribution assessment and concentration-driven photopolymerization of corneal proteins. In all cases, a consistent riboflavin concentration gradient, with lower levels in the central prepupillary zone, was recorded. Corneal topography and WA measurements showed significant corneal steepening and smooth wavefront shaping, respectively, with a delay in the central 2.0 mm of the WA and advancement in the surrounding zone, as well as a 50% reduction in corneal spherical aberration over a 5.0 mm pupil size. Notably, the corneal optical quality, measured via modulation transfer function (MTF), remained stable. This incision-free approach demonstrated the potential to extend focal range without compromising distance vision, presenting a new solution for presbyopia correction.

Theranostic-Guided UV-A Light Corneal Wavefront Photo-Reshaping for Presbyopia Correction: A Preclinical Study

Bernava G.
Secondo
;
Lombardo G.
Ultimo
2025

Abstract

This study investigated the effect of a theranostic-guided UV-A light corneal photo-reshaping technique on corneal elevation and wavefront aberration (WA) in human donor eyes. A specialized platform, combining UV-A light with corneal iontophoresis for controlled, patterned, riboflavin delivery, was used for both distribution assessment and concentration-driven photopolymerization of corneal proteins. In all cases, a consistent riboflavin concentration gradient, with lower levels in the central prepupillary zone, was recorded. Corneal topography and WA measurements showed significant corneal steepening and smooth wavefront shaping, respectively, with a delay in the central 2.0 mm of the WA and advancement in the surrounding zone, as well as a 50% reduction in corneal spherical aberration over a 5.0 mm pupil size. Notably, the corneal optical quality, measured via modulation transfer function (MTF), remained stable. This incision-free approach demonstrated the potential to extend focal range without compromising distance vision, presenting a new solution for presbyopia correction.
2025
Istituto per i Processi Chimico-Fisici - IPCF - Sede Messina
corneal iontophoresis
patterned drug delivery
presbyopia
riboflavin
theranostics
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/583014
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ente

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact