Biomarkers in interstitial fluid (ISF) can support minimally invasive diagnostics, but reliable ISF collection remains technically challenging due to the need for microneedles (MNs) that combine mechanical robustness with efficient fluid uptake. Here, poly(ethylene glycol) diacrylate (PEGDA)-based hydrogel MNs reinforced with aluminium oxide (Al2O3) nanoparticles (NPs) were fabricated through a mold-free photolithographic process and systematically evaluated. NP incorporation increased apparent stiffness up to 16-fold (from 0.15 ± 0.03 to 2.5 ± 0.1 N mm−1) while preserving high swelling capacity (25–28%). Among four formulations considered, only MN1 (PEGDA with 40 nm Al2O3 NPs in tripropylene glycol diacrylate – TPGDA – carrier) achieved successful indentation of an agarose-parafilm (PF) skin model, owing to its favorable NP dispersion and sharp tip geometry. MN1 also enabled measurable extraction of fluorescent tracers and glucose. These results identify MN1 as a mechanically robust, swellable, and promising platform, that combines penetration capability with analyte uptake in simplified in vitro models, highlighting its potential for future minimally invasive ISF-sampling applications.

Al2O3-reinforced PEGDA hydrogel microneedles designed for minimally invasive interstitial fluid glucose sampling

Stefania Dello Iacono
Co-primo
Conceptualization
;
Mario Battisti
Co-primo
Conceptualization
;
Eugenio Amendola;Brunella Corrado;Luca De Stefano;Maria Mangini
Methodology
;
Anna Chiara De Luca
Methodology
;
2026

Abstract

Biomarkers in interstitial fluid (ISF) can support minimally invasive diagnostics, but reliable ISF collection remains technically challenging due to the need for microneedles (MNs) that combine mechanical robustness with efficient fluid uptake. Here, poly(ethylene glycol) diacrylate (PEGDA)-based hydrogel MNs reinforced with aluminium oxide (Al2O3) nanoparticles (NPs) were fabricated through a mold-free photolithographic process and systematically evaluated. NP incorporation increased apparent stiffness up to 16-fold (from 0.15 ± 0.03 to 2.5 ± 0.1 N mm−1) while preserving high swelling capacity (25–28%). Among four formulations considered, only MN1 (PEGDA with 40 nm Al2O3 NPs in tripropylene glycol diacrylate – TPGDA – carrier) achieved successful indentation of an agarose-parafilm (PF) skin model, owing to its favorable NP dispersion and sharp tip geometry. MN1 also enabled measurable extraction of fluorescent tracers and glucose. These results identify MN1 as a mechanically robust, swellable, and promising platform, that combines penetration capability with analyte uptake in simplified in vitro models, highlighting its potential for future minimally invasive ISF-sampling applications.
2026
Istituto degli Endotipi in Oncologia, Metabolismo e Immunologia "G. Salvatore" (IEOMI) - Sede Secondaria c/o AdR Napoli 1
Istituto di Scienze Applicate e Sistemi Intelligenti "Eduardo Caianiello" - ISASI - Sede Secondaria Napoli
microneedles, diagnostics, glucose sampling
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/609003
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact