Using the Monte Carlo simulation tool GEANT4 we simulated the hadron-therapy beam line of the CATANA center. CATANA is the unique italian hadron-therapy facility in which 62 AMeV proton beams are used for the radiotherapeutic treatment of choroidal and iris melanomas. All the elements, such as diffusers, range shifters, collimators and detectors, typical of a proton-therapy line were modelled. The CATANA beam line provides an ideal environment for the experimental testing and validation of the software developed. The software architecture was developed, and now the validation of the software is in its final stage. Simulated ranges, energy distribution, depth and lateral dose distributions for full energy proton beams will be compared to the experimental results obtained at LNS with different detectors.

Implementation of a new Monte Carlo simulation tool for the development of a proton therapy beam line and verification of the related dose distributions

Russo;
2003

Abstract

Using the Monte Carlo simulation tool GEANT4 we simulated the hadron-therapy beam line of the CATANA center. CATANA is the unique italian hadron-therapy facility in which 62 AMeV proton beams are used for the radiotherapeutic treatment of choroidal and iris melanomas. All the elements, such as diffusers, range shifters, collimators and detectors, typical of a proton-therapy line were modelled. The CATANA beam line provides an ideal environment for the experimental testing and validation of the software developed. The software architecture was developed, and now the validation of the software is in its final stage. Simulated ranges, energy distribution, depth and lateral dose distributions for full energy proton beams will be compared to the experimental results obtained at LNS with different detectors.
2003
Inglese
2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference;Portland, OR;19 October 2003through25 October 2003
2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference
3
1756
1758
2
Sì, ma tipo non specificato
19 October 2003through25 October 2003
Portland
GEANT4; Hadrontherapy; Monte Carlo; Simulation
18
none
Cirrone, ; Gapa, ; Cuttone, ; Gb, ; Guatelli, ; Sc, ; Lo, Nigro; Sa, ; Mascialino, ; Bc, ; Pia, ; Mgc, ; Raffaele, ; Lb, ; Russo, Giorgio; Gb, ; Sabin...espandi
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/689
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact