Diagnosis of vertebral deformation and fracture is a key issue in the management of osteoporosis. Vertebral morphometry is the key solution to assess these vertebral deformities, but it is a tedious operation for the rheumatologist. In this paper, we propose an automatic approach to localize vertebrae and determine the vertebral morphometry. Based on a local phase symmetry measure, our approach shows promising results even on poor quality images. This work was tested on 22 scans of conventional lateral X-rays radiographs and compared to the results obtained by a trained radiologist. It resulted to have acceptable low error rates for localization and vertebral morphometry measures, but with a lack of robustness among images. Amelioration is necessary for images with an unoptimized patient positioning, when the X-ray beam is not perpendicular to the spine.

Automatic Vertebral Morphometry Assessment

Casciaro S;
2007

Abstract

Diagnosis of vertebral deformation and fracture is a key issue in the management of osteoporosis. Vertebral morphometry is the key solution to assess these vertebral deformities, but it is a tedious operation for the rheumatologist. In this paper, we propose an automatic approach to localize vertebrae and determine the vertebral morphometry. Based on a local phase symmetry measure, our approach shows promising results even on poor quality images. This work was tested on 22 scans of conventional lateral X-rays radiographs and compared to the results obtained by a trained radiologist. It resulted to have acceptable low error rates for localization and vertebral morphometry measures, but with a lack of robustness among images. Amelioration is necessary for images with an unoptimized patient positioning, when the X-ray beam is not perpendicular to the spine.
2007
Istituto di Fisiologia Clinica - IFC
Inglese
Proceedings of the 29th Annual International Conference of the IEEE EMBS
IEEE EMBC 2007 (29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society)
5571
5574
4
1-4244-0788-5
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=4353609
Sì, ma tipo non specificato
23-26 Agosto 2007
Lyon, France
automatic segmentation
vertebral fracture
morphometry
osteoporosis
X-ray images
2
restricted
Casciaro, S; Massoptier, L
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
File Dimensione Formato  
prod_81347-doc_96028.pdf

solo utenti autorizzati

Descrizione: Articolo pubblicato
Dimensione 562.26 kB
Formato Adobe PDF
562.26 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/72000
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 7
social impact