The use of an acetylcholinesterase inhibition assay for the detection of dichlorvos in durum wheat samples by a simplified extraction procedure is reported. After an incubation step, the residual activity was determined with an amperometric biosensor using a portable potentiostat. The use of electric eel and recombinant acetylcholinesterase was compared. The effect of the matrix extract was evaluated by using various sample:solvent ratios, 1:2.5, 1:5, 1:10, and 1:20. The optimal extraction ratio, considering the electrochemical interferences and the effect on enzyme activity and bioavailability of the pesticide, was 1:10. Calibrations were performed in buffer and durum wheat extract. The calculated detection limits in buffer solution were 10 ng/ml and 0.045 ng/ml for electric eel and recombinant acetylcholinesterase, respectively, whereas operating in the matrix extract they increased up to 45 ng/ml and 0.07 ng/ml, corresponding to 0.45 mg/kg (extraction ratio 1:10) and 0.07 mg/kg in samples. These characteristics allowed the detection of contaminated samples at the maximum residue limit, which is 2 mg/kg and well below. Fortified samples of durum wheat were obtained with both dichlorvos and the commercial product Didivane, which contains dichlorvos as an active molecule. At all the tested levels, the occurrence of contaminant was detected with an average recovery of 75%. The total assay time, including the extraction step, was 30 min. Because several extractions as well as most of the assay steps can be run simultaneously, the throughput for one operator is 12 determinations per hour.

An electrochemical bioassay for dichlorvos analysis in durum wheat samples

Visconti A;
2006

Abstract

The use of an acetylcholinesterase inhibition assay for the detection of dichlorvos in durum wheat samples by a simplified extraction procedure is reported. After an incubation step, the residual activity was determined with an amperometric biosensor using a portable potentiostat. The use of electric eel and recombinant acetylcholinesterase was compared. The effect of the matrix extract was evaluated by using various sample:solvent ratios, 1:2.5, 1:5, 1:10, and 1:20. The optimal extraction ratio, considering the electrochemical interferences and the effect on enzyme activity and bioavailability of the pesticide, was 1:10. Calibrations were performed in buffer and durum wheat extract. The calculated detection limits in buffer solution were 10 ng/ml and 0.045 ng/ml for electric eel and recombinant acetylcholinesterase, respectively, whereas operating in the matrix extract they increased up to 45 ng/ml and 0.07 ng/ml, corresponding to 0.45 mg/kg (extraction ratio 1:10) and 0.07 mg/kg in samples. These characteristics allowed the detection of contaminated samples at the maximum residue limit, which is 2 mg/kg and well below. Fortified samples of durum wheat were obtained with both dichlorvos and the commercial product Didivane, which contains dichlorvos as an active molecule. At all the tested levels, the occurrence of contaminant was detected with an average recovery of 75%. The total assay time, including the extraction step, was 30 min. Because several extractions as well as most of the assay steps can be run simultaneously, the throughput for one operator is 12 determinations per hour.
2006
Istituto di Scienze delle Produzioni Alimentari - ISPA
ORGANOPHOSPHATE PESTICIDES
DROSOPHILA-MELANOGASTER
BIOSENSOR
INSECTICIDE
SENSOR
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/73624
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 12
social impact